MedElevator Войти в исследования
← Поиск публикаций

DOI 10.36660/abc.20190252

Медицинская библиотека · Arquivos brasileiros de cardiologia · 2020

Percutaneous Transseptal Bioprosthetic Implantation in Failed Prosthetic Surgical Mitral Valve - Brazilian Multicenter Experience.

Nicz Pedro Felipe Gomes, Melo Pedro Henrique M Craveiro de, Brito Pedro Henrique Ferro de, Lima Eliane Nogueira, Silva Ricardo Cavalcante E, Prudente Maurício Lopes, Fernandes Fernando Henrique, Deininger Maurilio Onofre, Lopes Marcelo Antônio Cartaxo Queiroga, Petrucci Fúlvio Soares, Reis Filho Fernando Roquette, Marino Marcos Antonio, Bernardes Rodrigo de Castro, Melo Eduardo Pessoa de, Oliveira Marco Antonio Praça, Mangione José Armando, Mangione Fernanda Marinho, Falcão Carlos Henrique Eiras, Martins Estêvão Carvalho de Campos, Lunardi Walter, Bacal Fernando, Tarasoutchi Flávio, Brito Fábio Sândoli de

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Percutaneous intervention in patients with bioprosthetic mitral valve dysfunction is an alternative to conventional surgical treatment.

OBJECTIVES

To report the first Brazilian experience with transseptal transcatheter bioprosthetic mitral valve-in-valve implantation (transseptal-TMVIV).

METHODS

Patients with surgical bioprosthetic dysfunction submitted to transseptal-TMVIV in 12 Brazilian hospitals were included. The significance level adopted was p<0.05.

RESULTS

From June/2016 to February/2019, 17 patients underwent transseptal-TMVIV. Their median age was 77 years (IQR,70-82) and median Society of Thoracic Surgeons predicted risk of mortality (STS-PROM) score was 8.7% (IQR,7.2-17.8). All patients had limiting symptoms of heart failure (FC≥III) and 5 (29.4%) had undergone more than one previous thoracotomy. Transseptal-TMVIV was successful in all patients. Echocardiographic assessment showed a significant reduction in mean mitral valve gradient (pre-intervention, 12±3.8 mmHg; post-intervention, 5.3±2.6 mmHg; p<0.001), in addition to an increase in mitral valve area (pre-intervention, 1.06±0.59 cm2; post-intervention, 2.18±0.36 cm2; p<0.001) sustained for 30 days. There was a significant and immediate reduction in the pulmonary artery systolic pressure, with an additional reduction in 30 days (pre-intervention, 68.9±16.4 mmHg; post-intervention, 57.7±16.5 mmHg; 30 days, 50.9±18.7 mmHg; p<0.001). During follow-up (median, 162 days; IQR, 102-411), significant clinical improvement (FC≤II) was observed in 87.5% of the patients. One patient (5.9%) had left ventricular outflow tract (LVOT) obstruction and died right after the procedure, and another died at 161 days of follow-up.

CONCLUSION

The first Brazilian experience with transseptal-TMVIV shows the safety and effectivity of the new technique. The LVOT obstruction is a potentially fatal complication, reinforcing the importance of patients' selection and of procedural planning. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0).

Для цитирования: Nicz Pedro Felipe Gomes, Melo Pedro Henrique M Craveiro de, Brito Pedro Henrique Ferro de, Lima Eliane Nogueira, Silva Ricardo Cavalcante E, Prudente Maurício Lopes, Fernandes Fernando Henrique, Deininger Maurilio Onofre, Lopes Marcelo Antônio Cartaxo Queiroga, Petrucci Fúlvio Soares, Reis Filho Fernando Roquette, Marino Marcos Antonio, Bernardes Rodrigo de Castro, Melo Eduardo Pessoa de, Oliveira Marco Antonio Praça, Mangione José Armando, Mangione Fernanda Marinho, Falcão Carlos Henrique Eiras, Martins Estêvão Carvalho de Campos, Lunardi Walter, Bacal Fernando, Tarasoutchi Flávio, Brito Fábio Sândoli de. Percutaneous Transseptal Bioprosthetic Implantation in Failed Prosthetic Surgical Mitral Valve - Brazilian Multicenter Experience.. Arquivos brasileiros de cardiologia. 2020. DOI: 10.36660/abc.20190252.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.