Titanium alloy pins versus stainless steel pins in external fixation at the wrist: a randomized prospective study.

Pieske Oliver, Geleng Patrizia, Zaspel Johannes, Piltz Stefan

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Pin-track complications remain the most troublesome disadvantages of external fixation. The purpose of this study was to compare pin-related complications and pain levels after the use of external fixation for the stabilization of distal radial fractures with pins composed of two different materials.

METHODS

In a prospective trail 80 patients (320 pins) with unstable distal radial fracture were randomized for standard small AO-external fixator treatment with the use of identical pin geometry either composed of stainless-steel (Ss) (n = 40) or titanium alloy (Ti6Al4V) (n = 40). The patients were followed at biweekly intervals until the external fixators were removed (44 days after surgery). The patients were evaluated with regard to erythema, drainage, cellulitis, occurrence of pain at each pin-site, clinical or radiographic evidence of pin-loosening, the need for antibiotics, and the need for pin removal before fracture-healing due to infection.

RESULTS

The complication rate was 21%, and age was found to be significantly associated with an increased risk of pin-loosening (p = 0.003). There were no significant differences among the two groups with regard to the prevalence of pin-site complications. However, the rate of premature removal of fixator because of severe pin-track infection (5% vs. 0%) and the rate of pin-loosening (10% vs. 5%) was higher in the Ss-pin group. Furthermore, pain values were significantly reduced in the Ti6Al4V-pin group.

CONCLUSIONS

The use of Ti6Al4V-pin external fixator in distal radial fractures yields a trend of reduced pin-related complications and significantly reduced pain levels than does the Ss-pin fixator.

Для цитирования: Pieske Oliver, Geleng Patrizia, Zaspel Johannes, Piltz Stefan. Titanium alloy pins versus stainless steel pins in external fixation at the wrist: a randomized prospective study.. The Journal of trauma. 2008. DOI: 10.1097/ta.0b013e31815e40e0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.