MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/anae.15865

Медицинская библиотека · Anaesthesia · 2022

Impact of direct laryngoscopy vs. videolaryngoscopy on signal quality of recurrent laryngeal nerve monitoring in thyroid surgery: a randomised parallel group trial.

Kriege M, Hilt J A, Dette F, Wittenmeier E, Meuser R, Staubitz J I, Musholt T J

Рандомизированное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

In thyroid surgery, intra-operative neuromonitoring signals of the recurrent laryngeal nerve can be detected by surface electrodes on a tracheal tube positioned at the vocal fold level. The incidence of difficult tracheal intubation in patients undergoing thyroidectomy for nodular goitre ranges from 5.3% to 20.5%. The aim of this study was to compare videolaryngoscopy with conventional direct laryngoscopy as methods for proper placement of the surface electrode to prevent insufficient intra-operative nerve signal quality. In this prospective randomised trial, adult patients requiring tracheal intubation during thyroid surgery were randomly allocated to two groups of C-MAC® (Macintosh style blade) videolaryngoscope or direct laryngoscopy using the Macintosh laryngoscope. Primary outcome was the incidence of insufficient signal electromyogram amplitude level (< 500 μV) after successful tracheal intubation. A total of 260 (130 per group) participants were analysed. An insufficient signal was more frequent with direct laryngoscopy (35/130, 27%), compared with C-MAC (12/130, 9%, p < 0.001). First-pass tracheal intubation success rate was lower with direct laryngoscopy (86/130 (66%)) compared with the C-MAC (125/130 (96%)) (p < 0.0001). Cormack and Lehane grade ≥ 3 was observed more frequently with direct laryngoscopy (16/130 (12%)), compared with the C-MAC (0/130, (0%)) (p < 0.0001). The results suggest that videolaryngoscopy has an impact on the quality of the initial intra-operative neuromonitoring signal in patients undergoing thyroid surgery, and this technique can provide optimised surface electrode positioning.

Для цитирования: Kriege M, Hilt J A, Dette F, Wittenmeier E, Meuser R, Staubitz J I, Musholt T J. Impact of direct laryngoscopy vs. videolaryngoscopy on signal quality of recurrent laryngeal nerve monitoring in thyroid surgery: a randomised parallel group trial.. Anaesthesia. 2022. DOI: 10.1111/anae.15865.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.