Comparison of the Chemiluminescence Immunoassay LIAISON® with the Radioimmunoassay for Aldosterone and Renin Measurement.

Uhrová Jana, Benáková Hana, Vaníčková Zdislava, Zima Tomáš

СтатьяПеревод в очереди

Аннотация

Determination of renin plasma levels is useful in the diagnosis of hypertension and in the therapeutic follow-up of hypertensive patients. Plasmatic concentration of renin decreases in patients with hypertension due to a primary hyperaldosteronism, contrary to renovascular hypertension where concentrations of renin and aldosterone are both elevated. Blood samples (serum, EDTA plasma) were analysed using two different chemiluminiscent methods CLIA LIAISON® and radioimmunoassay for aldosterone (IMMUNOTECH Beckman Coulter) and renin (Cisbio Bioassay) measurements were compared. We used both methods to ascertain the correlation between serum vs. EDTA plasma levels of aldosterone (RIA, CLIA) and renin (IRMA, CLIA) and to compare aldosterone to renin ratios for CLIA and for radioimmunoassay: serum aldosterone to plasma renin and plasma aldosterone to plasma renin. We compared serum aldosterone CLIA vs. RIA (rP=0.933, P<0.001) and plasma renin determined using CLIA vs. IRMA (rP=0.965, P=0.062). Furthermore, we used both methods to establish the correlation between the serum vs. plasma levels of aldosterone: RIA (rP=0.980, P<0.001); CLIA (rP=0.994, P=0.353) and serum vs. plasma levels of renin: IRMA (rP=0.948, P<0.001); CLIA (rP=0.921, P=0.011). Aldosterone (serum, plasma) to plasmatic renin ratios for CLIA (rP=0.999, P=0.286) and for radioimmunoassay (rP=0.992, P=0.025). Our data demonstrate that renin and aldosterone concentrations obtained using CLIA correlate with renin and aldosterone concentrations using radioimmunoassay methods. Correlation coefficients of pair results ranged from 0.921 to 0.994. Aldosterone (serum, EDTA plasma) to plasmatic renin ratios are comparable and any of them can be used with no significant differences found.

Для цитирования: Uhrová Jana, Benáková Hana, Vaníčková Zdislava, Zima Tomáš. Comparison of the Chemiluminescence Immunoassay LIAISON® with the Radioimmunoassay for Aldosterone and Renin Measurement.. Prague medical report. 2021. DOI: 10.14712/23362936.2021.9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.