Plasma and urine aldosterone to plasma renin activity ratio in the diagnosis of primary aldosteronism.

Bernini Giampaolo, Moretti Angelica, Orlandini Cinzia, Berti Piero, Miccoli Paolo, Bardini Michele, Taurino Chiara, Bernini Matteo, Salvetti Antonio

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To establish the best cut-off value of the aldosterone (ALD)/plasma renin activity (PRA) ratio when screening patients for primary aldosteronism. One hundred and six patients with primary aldosteronism and 100 essential hypertensive patients were investigated in rigorous standardized conditions.

METHODS

The ALD/PRA cut-off values were calculated from both the plasma and urine ALD/PRA ratio and analyzed by receiver operating characteristic (ROC) curve. In patients with PRA below 0.2 ng/ml/h [our radioimmunoassay detection limit], values were calculated both with PRA levels set at 0.2 ng/ml/h ('adjusted') and with PRA levels detected ('unadjusted') in the assay.

RESULTS

ROC analysis on the ALD/PRA ratio indicated that the best performance was obtained when the plasma ALD (ng/dl)/PRA ratio was used in comparison with that observed in the urine ALD (microg/day)/PRA ratio. In patients with primary aldosteronism, as a whole group, the cut-off value of 69 corresponded to the best compromise value between sensitivity (96%) and specificity (85%), with and without PRA adjustment. In patients with aldosterone-producing adenoma, the cut-off to obtain 100% sensitivity with high specificity (85%) proved to be 69, with and without PRA adjustment. In patients with bilateral adrenal hyperplasia, both with and without PRA adjustment, the best compromise between sensitivity (94%) and specificity (86%) was a cut-off value of 71.

CONCLUSION

The best cut-off to identify patients with primary aldosteronism, corresponding to 69, was obtained by using the plasma ALD/PRA ratio. Adjustment of PRA to 0.2 ng/ml/h does not interfere with calculation of the plasma ALD/PRA ratio cut-off.

Для цитирования: Bernini Giampaolo, Moretti Angelica, Orlandini Cinzia, Berti Piero, Miccoli Paolo, Bardini Michele, Taurino Chiara, Bernini Matteo, Salvetti Antonio. Plasma and urine aldosterone to plasma renin activity ratio in the diagnosis of primary aldosteronism.. Journal of hypertension. 2008. DOI: 10.1097/hjh.0b013e3282f61f8c.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.