Assessment of maxillary sinus volume for the sinus lift operation by three-dimensional magnetic resonance imaging.

Gray C F, Staff R T, Redpath T W, Needham G, Renny N M

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To calculate sinus and bone graft volumes and vertical bone heights from sequential magnetic resonance imaging (MRI) examinations in patients undergoing a sinus lift operation.

METHODS

MRI scans were obtained pre-operatively and at 10 days and 10 weeks post-operatively, using a 0.95 tesla MRI scanner and a three-dimensional (3D) magnetisation prepared, rapid acquisition gradient-echo (MP-RAGE) sequence.

RESULTS

Estimates of the bone graft volumes required for a desired vertical bone height were made from the pre-operative MRI scan. Measurements of the graft volumes and bone heights actually achieved were made from the post-operative scans. The MRI appearance of the graft changed between the 10 day and 10 week scans.

CONCLUSIONS

We have proposed a technique which has the potential to give the surgeon an estimate of the optimum volume of graft for the sinus lift operation from the pre-operative MRI scan alone and demonstrated its application in a single patient. Changes in the sequential MRI appearance of the graft are consistent with replacement of fluid by a matrix of trabecular bone.

Для цитирования: Gray C F, Staff R T, Redpath T W, Needham G, Renny N M. Assessment of maxillary sinus volume for the sinus lift operation by three-dimensional magnetic resonance imaging.. Dento maxillo facial radiology. 2000. DOI: 10.1038/sj/dmfr/4600518.