MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/euad188

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023

Delineation of conduction gaps of linear lesions during atrial fibrillation ablation using ultra-high-density mapping.

Hashimoto Kenji, Kimura Takehiro, Seki Yuta, Ibe Susumu, Yamashita Terumasa, Miyama Hiroshi, Fujisawa Taishi, Katsumata Yoshinori, Fukuda Keiichi, Takatsuki Seiji

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: Linear lesions are routinely created by radiofrequency catheter ablation. Unwanted electrical conduction gaps can be produced and are often difficult to ablate. This study aimed to clarify the characteristics of conduction gaps during atrial fibrillation ablation by analysing bidirectional activation maps using a high-density mapping system (RHYTHMIA).

METHODS AND

RESULTS

This retrospective study included 31 patients who had conduction gaps along pulmonary vein (PV) isolation or box ablation lesions. Activation maps were sequentially created during pacing from the coronary sinus and PV to reveal the earliest activation site, defined by the entrance and exit. The locations, length between the entrance and exit (gap length), and direction were analysed. Thirty-four bidirectional activation maps were drawn: 21 were box isolation lesions (box group), and 13 were PV isolation lesions (PVI group). Among the box group, nine conduction gaps were present in the roof region and 12 in the bottom region, while nine in right PV and four in left PV among the PVI group. Gap lengths in the roof region were longer than those in the bottom region (26.8 ± 11.8 vs. 14.5 ± 9.8 mm; P = 0.022), while those in right PV tended to longer than those in left PV (28.0 ± 15.3 vs. 16.8 ± 8.0 mm, P = 0.201).

CONCLUSION

The entrances and exits of electrical conduction gaps were separated, especially in the roof region, indicating that epicardial conduction might contribute to gap formation. Identifying the bidirectional conduction gap might indicate the location and direction of epicardial conduction.

Для цитирования: Hashimoto Kenji, Kimura Takehiro, Seki Yuta, Ibe Susumu, Yamashita Terumasa, Miyama Hiroshi, Fujisawa Taishi, Katsumata Yoshinori, Fukuda Keiichi, Takatsuki Seiji. Delineation of conduction gaps of linear lesions during atrial fibrillation ablation using ultra-high-density mapping.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2023. DOI: 10.1093/europace/euad188.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.