MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.amjcard.2023.08.120

Медицинская библиотека · The American journal of cardiology · 2023

Self-Expanding Transcatheter Aortic Valves Optimize Transvalvular Hemodynamics Independent of Intra- Versus Supra-Annular Design.

Brown James A, Yousef Sarah, Toma Catalin, Kliner Dustin, Serna-Gallegos Derek, Makani Amber, West David, Wang Yisi, Thoma Floyd, Pompeu Sá Michel, Sultan Ibrahim

Наблюдательное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

This study sought to characterize transvalvular hemodynamics during the first 30 days after transcatheter aortic valve implantation (TAVI) across various transcatheter heart valves (THVs), while adjusting for annular dimensions. This was an observational study of TAVIs from September 2021 to October 2022. The primary outcome was mean transvalvular pressure gradient (TVPG), measured using transthoracic echocardiography at day 0, day 1, and day 30 post-TAVI, and were compared across 3 THV, including the self-expandable intra-annular Portico (Abbott Vascular, Santa Clara, California) valve, the balloon-expandable SAPIEN 3 Ultra (Edwards Lifesciences, Irvine, California), and the self-expandable supra-annular Evolut Pro+ (Medtronic, Minneapolis, Minnesota). A total of 560 patients who underwent TAVI were identified, of which 106 (18.9%) received a Portico THV, 176 (31.4%) received a SAPIEN THV, and 278 (49.6%) received an Evolut THV. For Portico THV, the TVPG on day 0 increased from 6.0 (4.7 to 9.0) to 7.0 (6.0 to 10.0) by day 30 (p = 0.009). For SAPIEN THV, the TVPG on day 0 increased from 6.5 (5.0 to 8.0) to 12.0 (9.0 to 15.0) by day 30 (p <0.001). For Evolut THV, the TVPG on day 0 increased from 6.0 (5.0 to 9.0) to 7.2 (5.0 to 10.0) by day 30 (p = 0.001). Adjusting for time and annular diameter in a multivariable mixed effects model, the SAPIEN group had a significantly greater increase in TVPG over time than the Evolut reference group (p <0.001), while there was no difference in the change of TVPG over time for the Portico group vs. the Evolut group (p = 0.874). In conclusion, compared with balloon-expandable valves, self-expanding THV may optimize transvalvular hemodynamics across all annular diameters, independent of their supra-annular and intra-annular design.

Для цитирования: Brown James A, Yousef Sarah, Toma Catalin, Kliner Dustin, Serna-Gallegos Derek, Makani Amber, West David, Wang Yisi, Thoma Floyd, Pompeu Sá Michel, Sultan Ibrahim. Self-Expanding Transcatheter Aortic Valves Optimize Transvalvular Hemodynamics Independent of Intra- Versus Supra-Annular Design.. The American journal of cardiology. 2023. DOI: 10.1016/j.amjcard.2023.08.120.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.