DOI 10.1002/ccd.30828

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2023

Patient-specific commissural alignment for ACURATE neo2 implantation in degenerated surgical bioprostheses.

Curio Jonathan, Khokhar Arif A, Beneduce Alessandro, Mylotte Darren, Fezzi Simone, Kim Won-Keun, Zlahoda-Huzior Adriana, Giannini Francesco, Dudek Dariusz

СтатьяПеревод пока не подготовлен

Аннотация

Valve-in-valve TAVI to treat failing surgical aortic valves (SAVs) is increasingly performed, and commissural alignment is a key technical aspect in such procedures. Surgeons optimize valve alignment, accounting for potential coronary eccentricity and achieving a patient-specific optimized commissural orientation, representing the ideal target for TAVI alignment. Therefore, here we present a dedicated stepwise valve-in-valve implantation technique using the ACURATE neo2. In a specific SAV postoverlap view, isolating one surgical post to the right of the screen representing the target for alignment, rotational orientation of the TAVI commissures, matching the SAV orientation, is achieved and verified before implantation. This technique has been tested in a patient-specific three-dimensionally-printed aortic root anatomy, attached to a pulsatile flow simulator, allowing for native-like simulation of coronary cannulations under fluoroscopy, and enabling detailed assessment with fluoroscopic as well as direct videographic visualization. Furthermore, the technique is exemplified by providing an educational clinical case example.

Для цитирования: Curio Jonathan, Khokhar Arif A, Beneduce Alessandro, Mylotte Darren, Fezzi Simone, Kim Won-Keun, Zlahoda-Huzior Adriana, Giannini Francesco, Dudek Dariusz. Patient-specific commissural alignment for ACURATE neo2 implantation in degenerated surgical bioprostheses.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2023. DOI: 10.1002/ccd.30828.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.