Plasma Neurofilament Light Chain Is Elevated after Transcatheter Aortic Valve Implantation.

Sjölin Karl, Christersson Christina, James Stefan, Lindbäck Johan, Åsberg Signild, Burman Joachim

Наблюдательное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Transcatheter aortic valve implantation (TAVI) is associated with a high incidence of new silent brain infarcts (SBIs) on postprocedural neuroimaging. A venous blood sample reflecting neuronal damage following TAVI could help identify patients with potential SBIs. We aimed to investigate if a biochemical marker of neuronal injury, neurofilament light chain (NFL), is elevated after TAVI.

METHODS

In this observational study, NFL was measured in plasma from 31 patients before and after TAVI. Multivariable regression analysis was performed to investigate any effect of clinical- and procedure-related factors on differences in NFL levels before and after TAVI.

RESULTS

Samples were collected 41 (14-81) days before and 44 (35-59) days after TAVI, median (interquartile range). Median age was 81 (77-84) years, and 35% were female. No patient had any overt procedure-related neurological complications. The geometric mean (95% confidence interval) of the NFL concentration was 30 (25-36) pg/mL before TAVI and 48 (39-61) pg/mL, after TAVI, p <0.001. None of the included variables in the multiple linear regression model were statistically significantly associated with the difference in levels before and after TAVI.

CONCLUSIONS

NFL levels in plasma were higher after TAVI as compared with levels before, with a mean increase of 60% (18 pg/mL). Further studies including neuroimaging and cognitive outcomes are needed to understand the potential value of measuring NFL in relation to TAVI.

Для цитирования: Sjölin Karl, Christersson Christina, James Stefan, Lindbäck Johan, Åsberg Signild, Burman Joachim. Plasma Neurofilament Light Chain Is Elevated after Transcatheter Aortic Valve Implantation.. Cardiology. 2023. DOI: 10.1159/000532041.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.