m+Medelevator.RU
← Поиск публикаций
European radiology · 2023

CT annulus sizing prior to transcatheter aortic valve replacement (TAVR): evaluation of free-breathing versus breath-holding acquisition.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Cour Adrien, Burel Julien, Garnier Matthieu, Durand Eric, Demeyere Matthieu, Dacher Jean-Nicolas

Аннотация

OBJECTIVES: To assess feasibility and accuracy of aortic annulus measurements using cardiac computed tomography angiography (CTA) performed during free-breathing prior to transcatheter aortic valve replacement (TAVR).

MATERIALS AND METHODS: Sixty consecutive TAVR candidates underwent free-breathing wide-detector cardiac CTA, followed by a percutaneous valve replacement. For each, a theoretical valve size was suggested through CT measurements of the annulus, then compared to the size of the actual implanted transcatheter heart valve (THV). The procedural success and the 30-day outcomes were collected. Image quality of the annulus was also studied according to subjective and objective criteria. Data of a control group of 60 patients previously evaluated on breath-holding were also evaluated.

RESULTS: A total of 120 patients (mean age, 83 years ± 7, 60 men) were evaluated. All CT acquisitions provided sufficient image quality allowing precise annulus measurements. Mean attenuation (p < 0.001) and image noise (p = 0.01) were higher in the free-breathing group, while image quality was comparable (p = 0.36). The agreement rate between CT-suggested valve size and THV implanted size was comparable, estimated at 87% (κ = 0.79, 95%CI 0.566, 0.908) on free-breathing vs. 82% (κ = 0.78, 95%CI 0.634, 0.904) on breath-holding. The procedure was successful for all patients without increase in 30-day mortality or adverse events.

CONCLUSIONS: Free-breathing cardiac CTA allows accurate aortic annulus measurements without compromising image quality or patients' outcome after TAVR. Elderly patients experiencing dyspnea, discomfort, or hearing loss that could prevent proper breath-holding should not be excluded from CT prior to TAVR.

CLINICAL RELEVANCE STATEMENT: To decrease elderly patients' discomfort, MDCT evaluation prior to transcatheter aortic valve replacement (TAVR) may be performed on quiet breathing with no significant impact on the outcome.

KEY POINTS: • Adhering to CT breathing commands can be challenging for patients with dyspnea, hearing impairment, agitation, or pulmonary diseases. • Free-breathing cardiac CT may be an alternative to breath-holding for patients unable to follow the breathing commands. • Wide-detector CT acquisition on free-breathing does not impair annulus measurements and prosthesis sizing in patients scheduled for TAVR.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты