MedElevator Войти в исследования
← Поиск публикаций

DOI 10.36660/abc.20220701

Медицинская библиотека · Arquivos brasileiros de cardiologia · 2023

Transcatheter Valve Replacement in Patients with Aortic Valve Stenosis: An Overview of Systematic Reviews and Meta-Analysis with Different Populations.

Diegoli Henrique, Alves Marcia Regina Dias, Okumura Lucas Miyake, Kroll Caroline, Silveira Dayane, Furlan Luiz Henrique Picolo

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Randomized controlled trials (RCTs) and observational studies have compared the efficacy and safety of transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with severe aortic stenosis.

OBJECTIVES

Compare TAVR and SAVR in patients with different surgical risks, population characteristics, and different transcatheter prosthetic valves.

METHODS

An overview of systematic reviews (SRs) was conducted following a structured protocol. Results were grouped by surgical risk, population characteristics, and different valves. RCTs in the SRs were reanalyzed through meta-analyses, and the results were summarized using the GRADE method. The adopted level of statistical significance was 5%.

RESULTS

Compared to SAVR, patients with high surgical risk using TAVR had a lower risk of (odds ratio, 95% confidence interval, absolute risk difference) atrial fibrillation (AF) (0.5, 0.29-0.86, -106/1000) and life-threatening bleeding (0.29, 0.2-0.42, -215/1000). Patients with intermediate surgical risk had a lower risk of AF (0.27, 0.23-0.33, -255/1000), life-threatening bleeding (0.15, 0.12-0.19, -330/1000), and acute renal failure (ARF) (0.4, 0.26-0.62, -21/1000). Patients with low surgical risk had a lower risk of death (0.58, 0.34-0.97, -16/1000), stroke (0.51, 0.28-0.94, -15/1000), AF (0.16, 0.12-0.2, -295/1000), life-threatening bleeding (0.17, 0.05-0.55, -76/1000), and ARF (0.27, 0.13-0.55, -21/1000), and had a higher risk of permanent pacemaker implantation (PPI) (4.22, 1.27-14.02, 141/1000). Newer generation devices had a lower risk of AF than older generations, and patients using balloon-expandable devices did not experience higher risks of PPI.

CONCLUSIONS

This paper provides evidence that patients at low, intermediate, and high surgical risks have better outcomes when treated with TAVR compared with SAVR.

Для цитирования: Diegoli Henrique, Alves Marcia Regina Dias, Okumura Lucas Miyake, Kroll Caroline, Silveira Dayane, Furlan Luiz Henrique Picolo. Transcatheter Valve Replacement in Patients with Aortic Valve Stenosis: An Overview of Systematic Reviews and Meta-Analysis with Different Populations.. Arquivos brasileiros de cardiologia. 2023. DOI: 10.36660/abc.20220701.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.