Comparison of contemporary transcatheter heart valve prostheses: data from the German Aortic Valve Registry (GARY).

Rudolph Tanja K, Herrmann Eva, Bon Dimitria, Walther Thomas, Bauer Timm, Ensminger Stephan, Frerker Christian, Beckmann Andreas, Möllmann Helge, Bekeredjian Raffi, Beyersdorf Friedhelm, Hamm Christian, Baldus Stephan, Böning Andreas, Gummert Jan, Rudolph Volker, Bleiziffer Sabine

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Various second-generation transcatheter heart valve (THV) prostheses with high clinical efficacy and safety are available, but there is limited large-scale data available comparing their hemodynamic performance and clinical implications.

OBJECTIVE

To compare the hemodynamic performance and short-term clinical outcome of four second-generation THV prostheses.

METHODS

24,124 patients out of the German Aortic Valve Registry who underwent transfemoral transcatheter aortic valve implantation (TAVI) (Evolut™ R n = 7028, Acurate neo™ n = 2922, Portico n = 878 and Sapien 3 n = 13,296) were included in this analysis. Propensity-score weighted analysis was performed to control for differences in age, left ventricular function, STS score and sex. Primary endpoint was survival at one-year, secondary endpoints were 30 days survival, pre-discharge transvalvular gradients, paravalvular leakage and peri-procedural complications.

RESULTS

Thirty-day and one-year survival were not significantly different between the four patient groups. Transvalvular gradients in Evolut™ R and Acurate neo™ were significantly lower as compared to Portico and Sapien 3 at hospital discharge. This difference exists across all annulus sizes. Paravalvular leakage ≥ II occurred significantly less often in the Sapien 3 group (1.2%, p < 0.0001). Rate of severe procedural complications was low and comparable in all groups. Permanent pacemaker implantation rate at one year was lowest in the ACUARATE neo group (13.0%) and highest in the Evolut™ R group (21.9%).

CONCLUSION

Albeit comparable short-term clinical outcomes there are certain differences regarding hemodynamic performance and permanent pacemaker implantation rate between currently available THV prostheses which should be considered for individual prosthesis selection.

Для цитирования: Rudolph Tanja K, Herrmann Eva, Bon Dimitria, Walther Thomas, Bauer Timm, Ensminger Stephan, Frerker Christian, Beckmann Andreas, Möllmann Helge, Bekeredjian Raffi, Beyersdorf Friedhelm, Hamm Christian, Baldus Stephan, Böning Andreas, Gummert Jan, Rudolph Volker, Bleiziffer Sabine. Comparison of contemporary transcatheter heart valve prostheses: data from the German Aortic Valve Registry (GARY).. Clinical research in cardiology : official journal of the German Cardiac Society. 2023. DOI: 10.1007/s00392-023-02242-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.