MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2019/7348964

Медицинская библиотека · Journal of interventional cardiology · 2019

Transcatheter Aortic Valve Replacement in Patients with Aortic Stenosis Having Coronary Cusp Fusion versus Mixed Cusp Fusion Nonraphe Bicuspid Aortic Valve.

Lei Wen-Hua, Liao Yan-Biao, Wang Zi-Jie, Ou Yuan-Weixiang, Tsauo Jiay-Yu, Li Yi-Jian, Xiong Tian-Yuan, Zhao Zhen-Gang, Wei Xin, Meng Wei, Feng Yuan, Chen Mao

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

We aimed to assess the procedural and clinical results of transcatheter aortic valve replacement (TAVR) for nonraphe bicuspid aortic stenosis (AS) with coronary vs mixed cusp fusion.

BACKGROUND

It remains unclear whether cusp fusion morphology affects TAVR outcomes in patients with nonraphe bicuspid AS.

METHODS

This retrospective study enrolled consecutive patients with severe symptomatic AS and type-0 bicuspid aortic valve, who underwent TAVR at our institution between 2012 and 2017. TAVR outcomes were defined based on the Valve Academic Research Consortium-2 recommendations.

RESULTS

Compared to patients with mixed cusp fusion (44/71), those with coronary cusp fusion (27/71) had a larger ellipticity index for the aortic annulus (21.9% ± 9.0% vs 15.6% ± 9.3%, p=0.007) and increased left ventricular outflow tract obstruction (31.1% ± 9.4% vs 26.9% ± 7.5%, p=0.04) but comparable rates of second valve implantation (15.9% vs 14.8%), mild paravalvular leakage (PVL, 38.5% vs 30.2%), permanent pacemaker implantation (PPM, 25.9% vs 15.9%), and 30-day mortality (7.4% vs 6.8%). Use of a first-generation transcatheter heart valve was associated with higher risk for mild PVL (odds ratio (OR) = 4.37; 95% confidence interval (95% CI) = 1.14-16.75; p=0.03) but not PPM (OR = 0.77; 95% CI = 0.22-2.62; p=0.67), whereas a larger oversizing ratio tended to be associated with a higher PPM rate (OR = 1.49; 95% CI = 0.46-4.86; p=0.51) but lower incidence of mild PVL (OR = 0.51; 95% CI = 0.19-1.35; p=0.17).

CONCLUSIONS

In AS patients with type-0 bicuspid valves, cusp fusion morphology does not affect the procedural or clinical results of TAVR. Use of second-generation transcatheter heart valves may provide more favorable results in such patients. This trial is registered with NCT01683474.

Для цитирования: Lei Wen-Hua, Liao Yan-Biao, Wang Zi-Jie, Ou Yuan-Weixiang, Tsauo Jiay-Yu, Li Yi-Jian, Xiong Tian-Yuan, Zhao Zhen-Gang, Wei Xin, Meng Wei, Feng Yuan, Chen Mao. Transcatheter Aortic Valve Replacement in Patients with Aortic Stenosis Having Coronary Cusp Fusion versus Mixed Cusp Fusion Nonraphe Bicuspid Aortic Valve.. Journal of interventional cardiology. 2019. DOI: 10.1155/2019/7348964.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.