MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mds.20409

Медицинская библиотека · Movement disorders : official journal of the Movement Disorder Society · 2005

Feasibility and validity of a modified finger-nose-finger test.

Louis Elan D, Applegate Lakeisha M, Borden Sarah, Moskowitz Carol, Jin Zhezhen

СтатьяПоддержка NIH: внешняя программаПоддержка службы здравоохранения СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

In essential tremor (ET) research, it is important to obtain standardized, objective data on tremor severity. Often, it is not possible to carry out in-person or videotaped neurological examinations. In place of these, handwriting samples can be collected, but they do not capture all of the variance in tremor severity. Although additional tests of tremor severity (finger-nose-finger [FNF] test) might be of use, these would need to be modified to allow ET patients to mail their results to the study investigator for rating. We modified the standard FNF test (sFNF) by asking subjects to hold a pen during this activity and mark a paper target. The purpose of this report was to determine whether the modified FNF (mFNF) test was feasible and valid. Of 70 subjects, 65 (92.9%) were able to complete the mFNF, demonstrating that it was feasible. The scores of the mFNF correlated highly with those of the sFNF (r = 0.56-0.85; all P < 0.001), indicating the mFNF is a valid measure of tremor severity. In addition, using the regression equation, sFNF = 0.174(mFNF) + 0.743, a sFNF score can be derived easily from the mFNF score. The mFNF may be used to collect valuable data on tremor severity in pathological, genetic, and epidemiological field studies of ET, in which in-person or videotaped neurological examinations are not possible.

Для цитирования: Louis Elan D, Applegate Lakeisha M, Borden Sarah, Moskowitz Carol, Jin Zhezhen. Feasibility and validity of a modified finger-nose-finger test.. Movement disorders : official journal of the Movement Disorder Society. 2005. DOI: 10.1002/mds.20409.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.