Clinical research in cardiology : official journal of the German Cardiac Society · 2019

One year VARC-2-defined clinical outcomes after transcatheter aortic valve implantation with the SAPIEN 3.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Pellegrini Costanza, Rheude Tobias, Trenkwalder Teresa, Mayr N Patrick, Joner Michael, Kastrati Adnan, Schunkert Heribert, Husser Oliver, Hengstenberg Christian

Аннотация

AIMS: To evaluate 1-year outcome after transcatheter aortic valve implantation (TAVI) using the SAPIEN 3 (S3) prosthesis with emphasis on the composite endpoints "clinical efficacy after 30 days" and "time-related valve safety" proposed by the updated Valve Academic Research Consortium (VARC-2).

METHODS AND RESULTS: Four hundred and two consecutive patients undergoing transfemoral TAVI with the S3 were enrolled. Mean age was 81 ± 6 years, 43% were female and median logistic EuroSCORE I was 12% [8-19]. Device success was achieved in 93% (374/402) with moderate or severe paravalvular leakage (PVL) in 2%. At 1 year all-cause mortality was 8.9% [95% CI 6.4-12.2] and new permanent pacemaker implantation rate was 16% [95% CI 12.7-20.4]. The composite endpoint time-related valve safety occurred in 29% with structural valve deterioration, defined as elevated gradients or more than moderate PVL, occurring in 13%. The clinical efficacy endpoint after 30 days was observed in 37% of patients with the main contributor symptom worsening with New York Heart Association functional class III + in 17% of cases.

CONCLUSIONS: For the first time, VARC-2-defined composite endpoints at 1 year are reported and reveal a considerable proportion of patients experiencing the endpoint of time-related valve safety (29%) and clinical efficacy after 30 days (37%).