Cardiovascular revascularization medicine : including molecular interventions · 2019
Transcatheter versus surgical aortic valve replacement in low-risk surgical patients: A meta-analysis of randomized clinical trials.
СтатьяМетаанализСистематический обзорНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kheiri Babikir, Osman Mohammed, Abubakar Hossam, Subahi Ahmed, Chahine Adam, Ahmed Sahar, Bachuwa Ghassan, Alkotob Mohammad L, Hassan Mustafa, Bhatt Deepak L
Аннотация
BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a valid option for patients with high or intermediate surgical risk. However, clinical outcomes of TAVR in low-risk patients are lacking. Our aim was to evaluate the efficacy and safety of TAVR versus surgical aortic valve replacement (SAVR) in low-surgical-risk patients.
METHODS: Electronic database review was conducted for all randomized clinical trials (RCTs) that compared TAVR versus SAVR in low-risk patients. We calculated risk ratios (RRs) and 95% confidence intervals (CIs) using a random-effects model.
RESULTS: We included 3 RCTs totaling 604 patients (310 TAVR and 294 SAVR). Our results showed no significant difference in mortality between TAVR compared with SAVR (RR = 0.71; 95% CI = 0.22-2.30; P = 0.56), however, there was a significantly increased risk of pacemaker implantation (RR = 7.28; 95% CI = 3.94-13.42; P < 0.01) and moderate/severe paravalvular leakage (PVL) (RR = 6.74; 95% CI = 1.31-34.65; P = 0.02) with TAVR. Nevertheless, TAVR demonstrated a significantly reduced risk of post-procedural bleeding (RR = 0.40; 95% CI = 0.30-0.54; P < 0.01) and new-onset atrial fibrillation (RR = 0.36; 95% CI = 0.27-0.47; P < 0.01). Other clinical outcomes were not significantly different between the groups and included cardiovascular mortality, stroke, transient ischemic attack, and myocardial infarction.
CONCLUSIONS: Among low-risk patients, TAVR offered comparable efficacy outcomes and fewer bleeding events compared with SAVR. There were increased risks of pacemaker implantation and PVL associated with TAVR, though lower atrial fibrillation risks.
METHODS: Electronic database review was conducted for all randomized clinical trials (RCTs) that compared TAVR versus SAVR in low-risk patients. We calculated risk ratios (RRs) and 95% confidence intervals (CIs) using a random-effects model.
RESULTS: We included 3 RCTs totaling 604 patients (310 TAVR and 294 SAVR). Our results showed no significant difference in mortality between TAVR compared with SAVR (RR = 0.71; 95% CI = 0.22-2.30; P = 0.56), however, there was a significantly increased risk of pacemaker implantation (RR = 7.28; 95% CI = 3.94-13.42; P < 0.01) and moderate/severe paravalvular leakage (PVL) (RR = 6.74; 95% CI = 1.31-34.65; P = 0.02) with TAVR. Nevertheless, TAVR demonstrated a significantly reduced risk of post-procedural bleeding (RR = 0.40; 95% CI = 0.30-0.54; P < 0.01) and new-onset atrial fibrillation (RR = 0.36; 95% CI = 0.27-0.47; P < 0.01). Other clinical outcomes were not significantly different between the groups and included cardiovascular mortality, stroke, transient ischemic attack, and myocardial infarction.
CONCLUSIONS: Among low-risk patients, TAVR offered comparable efficacy outcomes and fewer bleeding events compared with SAVR. There were increased risks of pacemaker implantation and PVL associated with TAVR, though lower atrial fibrillation risks.
Предметные рубрики MeSH
AgedAged, 80 and overAortic ValveAortic Valve StenosisFemaleHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHemodynamicsHumansMalePostoperative ComplicationsRandomized Controlled Trials as TopicRecovery of FunctionRisk AssessmentRisk FactorsTranscatheter Aortic Valve ReplacementTreatment Outcome