Randomized controlled study of detection enhancements versus rate-only detection to prevent inappropriate therapy in a dual-chamber implantable cardioverter-defibrillator.

Dorian Paul, Philippon François, Thibault Bernard, Kimber Shane, Sterns Larry, Greene Mary, Newman David, Gelaznikas Robert, Barr Aiala, ASTRID Investigators

Клиническое исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

The purpose of this study was to compare rate-only detection to enhanced detection in a dual-chamber implantable cardioverter-defibrillator (ICD), to discriminate ventricular tachycardia from supraventricular tachycardia.

BACKGROUND

ICDs are highly effective in treating ventricular tachycardia (VT) or ventricular fibrillation (VF). However, they frequently deliver inappropriate therapy during supraventricular tachycardia (SVT).

METHODS

We conducted a randomized clinical trial of detection enhancements in a dual-chamber ICD compared to control (rate-only) detection to discriminate VT from SVT. Detection enhancements included a specific standardized protocol identical for all patients for programming rate stability, sudden onset, atrial-to-ventricular relationship (sudden onset = 9% and rate stability = 10 ms; V > A "on"), and "sustained rate duration" (3 minutes). The primary endpoint was the time to first inappropriate therapy classified by a blinded events committee.

RESULTS

One hundred forty-nine patients had a history of sustained VT or VF. Mean age (+/- SD) was 60 +/- 13 years; 83% were male, and mean ejection fraction was 35 +/- 15%. Control (n = 70) and "enhanced" (n = 79) groups did not differ with regard to age, sex, ejection fraction, or primary arrhythmia. The proportion of patients free of inappropriate therapy over time was significantly higher in the enhanced versus the control group (hazard ratio = 0.47, P = .011). High-energy shocks were reduced from 0.58 +/- 4.23 shocks/patient/month in the control group to 0.04 +/- 0.15 shocks/patient/month in the enhanced group (P = .0425). No patient programmed per protocol failed to receive therapy for VT detected by the ICD (422 VT episodes).

CONCLUSIONS

Standardized programming in a dual-chamber ICD leads to a significant and clinically important reduction in inappropriate therapies compared to rate-only detection and does not compromise safety with respect to appropriate treatment of VT.

Для цитирования: Dorian Paul, Philippon François, Thibault Bernard, Kimber Shane, Sterns Larry, Greene Mary, Newman David, Gelaznikas Robert, Barr Aiala, ASTRID Investigators. Randomized controlled study of detection enhancements versus rate-only detection to prevent inappropriate therapy in a dual-chamber implantable cardioverter-defibrillator.. Heart rhythm. 2004. DOI: 10.1016/j.hrthm.2004.07.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.