MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10439-017-1819-3

Медицинская библиотека · Annals of biomedical engineering · 2017

Handheld Electrical Impedance Myography Probe for Assessing Carpal Tunnel Syndrome.

Li Zhao, Chen Lingfen, Zhu Yu, Wei Qingquan, Liu Wenwen, Tian Dong, Yu Yude

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Electrical impedance myography (EIM) is a novel, noninvasive, and painless technique for quantitatively assessing muscle health as well as disease status and progression. The preparatory work for commercial adhesive electrodes used in previous EIM measurements is tedious, as the electrodes need to be cut, repeatedly applied, and removed. Moreover, the electrode distances need to be measured many times. To overcome these problems, we developed a convenient and practical handheld EIM probe for assessing carpal tunnel syndrome (CTS) in the small hand muscles. To reduce the electrode-skin contact impedance (ESCI), the micropillared and microholed stainless steel electrodes (SSEs) contained in the probe were fabricated using a laser processing technique. When covered with saline, these electrodes showed lower ESCIs than a smooth SSE and Ag/AgCl electrode. The probe was shown to have excellent test-retest reproducibility in both healthy subjects and CTS patients, with intraclass correlation coefficients exceeding 0.975. The reactance and phase values of the abductor pollicis brevis (affected muscle) for CTS patients were consistently lower than those for healthy subjects, with a 50-kHz difference of 37.1% (p < 0.001) and 31.0% (p < 0.001), respectively. Further, no significant differences were detected in the case of the abductor digiti minimi (unaffected muscle). These results indicate that EIM has considerable potential for CTS assessment and hence merits further investigation.

Для цитирования: Li Zhao, Chen Lingfen, Zhu Yu, Wei Qingquan, Liu Wenwen, Tian Dong, Yu Yude. Handheld Electrical Impedance Myography Probe for Assessing Carpal Tunnel Syndrome.. Annals of biomedical engineering. 2017. DOI: 10.1007/s10439-017-1819-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.