m+Medelevator.RU
← Поиск публикаций
The American journal of cardiology · 2002

Acute blood pressure effects at the onset of supraventricular and ventricular tachycardia.

Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Taneja Taresh, Kadish Alan H, Parker Michele A, Goldberger Jeffrey J

Аннотация

This study was designed to assess the effects of tachycardia origin, the significance of atrial contribution, and the effects of left ventricular ejection fraction on hemodynamically tolerated ventricular tachycardia (VT) and supraventricular tachycardia (SVT). Forty-one subjects with inducible hemodynamically tolerated VT (n = 24) or SVT (n = 17) with mean ages of 60 +/- 13 and 40 +/- 16 years and mean ejection fractions of 32 +/- 15% and 59 +/- 5%, respectively, were studied. VT and SVT were induced by standard techniques, and femoral arterial blood pressure (BP) was recorded for 30 seconds. After tachycardia termination, with >/=3 minutes between conditions, ventricular overdrive pacing was performed from the right ventricular (RV) apex and then the RV outflow tract, followed by atrioventricular (AV) pacing at the tachycardia cycle length. Mean BP was measured every 5 seconds. Linear regression methods were used to model BP response for the 2 groups. There was a significant increase in BP over the 20-second interval after the induction of VT and SVT (0.55 +/- 0.21 and 1.0 +/- 0.20 mm Hg/s, respectively, p <0.05). In patients with hemodynamically tolerated VT, RV apex and RV outflow tract pacing at the tachycardia cycle length decreased BP by 6.7 +/- 2.0 (p <0.002) and 4.7 +/- 2.5 mm Hg (p = 0.06), respectively. AV pacing at the tachycardia cycle length did not improve BP compared with RV pacing alone. In patients with SVT, RV apex and RV outflow pacing at the tachycardia cycle length decreased BP by 5.6 +/- 2.9 (p = 0.05) and 4.1 +/- 2.7 mm Hg (p = 0.12), respectively. However, AV pacing at the tachycardia cycle length was associated with improved BP response over RV pacing alone. Increased age and lower ejection fraction adversely influenced BP response in the VT group and longer cycle length, and higher preinduction BP favorably influenced BP response in the SVT group. The determinants of BP response after tachycardia onset are complex and differ in patients with SVT and VT.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты