MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2014.04.016

Медицинская библиотека · JACC. Cardiovascular interventions · 2014

Transapical transcatheter aortic valve for severe aortic regurgitation: expanding the limits.

Wendt Daniel, Kahlert Philipp, Pasa Susanne, El-Chilali Karim, Al-Rashid Fadi, Tsagakis Konstantinos, Dohle Daniel Sebastian, Erbel Raimund, Jakob Heinz, Thielmann Matthias

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study sought to evaluate the self-expandable ACURATE TA device (Symetis SA, Ecublens, Switzerland) in a cohort of patients with pure aortic regurgitation (AR).

BACKGROUND

Transcatheter aortic valve replacement (TAVR) has been initially considered as an alternative for high-risk patients with aortic stenosis. Although the current experience is limited, TAVR might be also an alternative to treat patients with pure, severe AR.

METHODS

Between April 2012 and December 2013, a total of 8 high-risk patients with pure, severe AR were enrolled (grade III+). Clinical and hemodynamic data as well as data on device and procedure parameters and outcomes were collected.

RESULTS

Patient mean was 72.5 ± 8.4 years, and 37.5% of patients were female. Logistic EuroSCORE was 34.0 ± 7.9% and the Society of Thoracic Surgeons score was 7.3 ± 3.3% on average. Two patients had undergone emergency aortic operation before due to acute type A aortic dissection, and both were treated by replacement of the ascending aorta (including root reconstruction) and the aortic arch combined with or without E-vita Open stent graft (Jotec GmbH, Hechingen, Germany) (January 2011 and March 2012), whereas the other patients experienced primary AR. All patients underwent successful transapical TAVR with the transapical ACURATE TA device (size small, n = 1, size medium, n = 3, size large, n = 4) without any intraprocedural complications according to the Valve Academic Research Consortium 2 criteria. Post-procedure AR grade I+ or lower, as revealed by transoesophageal echocardiography and angiography, was present in all 8 patients. At 30 days, the stroke incidence and all-cause mortality rate were 0%.

CONCLUSIONS

This small single-center series demonstrates the feasibility of transapical TAVR with the self-expandable ACURATE TA device in high-risk patients with severe AR.

Для цитирования: Wendt Daniel, Kahlert Philipp, Pasa Susanne, El-Chilali Karim, Al-Rashid Fadi, Tsagakis Konstantinos, Dohle Daniel Sebastian, Erbel Raimund, Jakob Heinz, Thielmann Matthias. Transapical transcatheter aortic valve for severe aortic regurgitation: expanding the limits.. JACC. Cardiovascular interventions. 2014. DOI: 10.1016/j.jcin.2014.04.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.