The Journal of heart valve disease · 2014
Does a minimally invasive approach increase the incidence of patient-prosthesis mismatch in aortic valve replacement?
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Bakir Ihsan, Casselman Filip P, Onan Burak, Van Praet Frank, Vermeulen Yvette, Degrieck Ivan
Аннотация
BACKGROUND AND AIM OF THE STUDY: The impact of a minimally invasive approach on patient-prosthesis mismatch (PPM) in patients undergoing aortic valve replacement (AVR) remains unknown. The study aim was to identify the impact of a minimally invasive approach for AVR on the incidence of PPM.
METHODS: The results of a single-center experience in 506 patients who underwent isolated AVR through a minimally invasive or conventional sternotomy were analyzed. Postoperative PPM was defined as an effective orifice area index < 0.85 cm2/m2, and was correlated with surgical approach, mortality and cardiac events after surgery.
RESULTS: Overall, postoperative PPM was present in 26.0% of the patients. The ratio of PPM was 24.1% in minimal access patients and 27.7% in conventional AVR patients (p = 0.35). Hospital mortality was similar in both groups (3.8% versus 3.4%, p = 0.62). The body mass index (BMI) was higher in patients with PPM (28.5 +/- 4.4 versus 25.3 +/- 3.6 kg/m2; p = 0.0001), but obesity was significantly associated with PPM (36.3% versus 9.4%; p = 0.0001). The PPM group included more patients with a left ventricular ejection fraction (LVEF) < 0.50 (12.8% versus 5.3%; p = 0.004). The independent risk factors for PPM were increased BMI (p = 0.0001), LVEF < 0.50 (p = 0.007) and preoperative aortic stenosis (p = 0.029). A LVEF < 0.50 increased the risk for PPM by 3.77-fold (95% CI: 1.4-9.9), while a high BMI increased the risk by 1.42-fold (95% CI: 1.3-1.5). Preoperative aortic insufficiency was associated with PPM, but did not significantly increase the risk.
CONCLUSION: A minimally invasive approach for AVR did not lead to an increased incidence of PPM and associated adverse events following surgery.
METHODS: The results of a single-center experience in 506 patients who underwent isolated AVR through a minimally invasive or conventional sternotomy were analyzed. Postoperative PPM was defined as an effective orifice area index < 0.85 cm2/m2, and was correlated with surgical approach, mortality and cardiac events after surgery.
RESULTS: Overall, postoperative PPM was present in 26.0% of the patients. The ratio of PPM was 24.1% in minimal access patients and 27.7% in conventional AVR patients (p = 0.35). Hospital mortality was similar in both groups (3.8% versus 3.4%, p = 0.62). The body mass index (BMI) was higher in patients with PPM (28.5 +/- 4.4 versus 25.3 +/- 3.6 kg/m2; p = 0.0001), but obesity was significantly associated with PPM (36.3% versus 9.4%; p = 0.0001). The PPM group included more patients with a left ventricular ejection fraction (LVEF) < 0.50 (12.8% versus 5.3%; p = 0.004). The independent risk factors for PPM were increased BMI (p = 0.0001), LVEF < 0.50 (p = 0.007) and preoperative aortic stenosis (p = 0.029). A LVEF < 0.50 increased the risk for PPM by 3.77-fold (95% CI: 1.4-9.9), while a high BMI increased the risk by 1.42-fold (95% CI: 1.3-1.5). Preoperative aortic insufficiency was associated with PPM, but did not significantly increase the risk.
CONCLUSION: A minimally invasive approach for AVR did not lead to an increased incidence of PPM and associated adverse events following surgery.
Предметные рубрики MeSH
AgedAged, 80 and overAortic ValveAortic Valve InsufficiencyAortic Valve StenosisBelgiumFemaleHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHospital MortalityHumansIncidenceMaleMiddle AgedMinimally Invasive Surgical ProceduresPostoperative ComplicationsProsthesis DesignRetrospective StudiesRisk FactorsSternotomyTime FactorsTreatment Outcome