MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/heartjnl-2013-305390

Медицинская библиотека · Heart (British Cardiac Society) · 2014

Device-dependent association between paravalvar aortic regurgitation and outcome after TAVI.

Dworakowski Rafal, Wendler Olaf, Halliday Brian, Ludman Peter, DeBelder Mark, Ray Simon, Moat Neil, Kovac Jan, Spyt Tomasz, Trivedi Uday, Hildick-Smith David, Blackman Dan, Marlee Damian, Cunningham David, MacCarthy Philip A

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

The aim of the current study was to identify predictors of paraprosthetic aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI) and examine its influence on short/medium-term mortality using the UK TAVI Registry. TAVI is an effective treatment for high-risk patients with severe symptomatic aortic stenosis (AS), but paraprosthetic AR has been associated with increased in-hospital and mid-term mortality.

METHODS

Between January 2007 and December 2011, 2584 TAVI procedures were performed in the UK. Patients undergoing 'valve-in-valve' procedures, patients with aortic regurgitation as the primary pathology and with no recorded severity of AR were excluded from this analysis (n=144). In total, therefore, 2440 patients were included. Balloon-expandable and self-expanding devices were implanted in 52.7 and 47.2%, respectively, using either transfemoral (67.7%) or non-transfemoral, surgical access (32.3%).

RESULTS

Postprocedural AR was observed in 68%, mild AR in 57% and moderate-severe in 10%. A large aortic annulus, high preprocedural transaortic gradient, and use of self-expanding valve were independent predictors of moderate-severe AR. Moderate-severe (but not mild) AR was associated with increased mortality, and this relationship appeared significant for the balloon-expandable but not the self-expanding device.

CONCLUSIONS

Our data suggest that a large aortic annulus, high preprocedural transaortic gradient, and use of the self-expanding valve predict moderate-severe AR after TAVI. Such a degree of AR is associated with a significantly worse outcome with the balloon-expandable, but not with the self-expanding valve. Further studies are needed to verify this and explore potential mechanisms.

Для цитирования: Dworakowski Rafal, Wendler Olaf, Halliday Brian, Ludman Peter, DeBelder Mark, Ray Simon, Moat Neil, Kovac Jan, Spyt Tomasz, Trivedi Uday, Hildick-Smith David, Blackman Dan, Marlee Damian, Cunningham David, MacCarthy Philip A. Device-dependent association between paravalvar aortic regurgitation and outcome after TAVI.. Heart (British Cardiac Society). 2014. DOI: 10.1136/heartjnl-2013-305390.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.