Texas Heart Institute journal · 2014
Staged balloon aortic valvuloplasty before standard aortic valve replacement in selected patients with severe aortic valve stenosis.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Altarabsheh Salah Eldien, Greason Kevin L, Schaff Hartzell V, Suri Rakesh M, Li Zhuo, Mathew Verghese, Joyce Lyle D, Park Soon J, Dearani Joseph A
Аннотация
This study evaluated preoperative balloon aortic valvuloplasty (BAV) as a technique to decrease aortic valve replacement (AVR) risk in patients who have severe symptomatic aortic valve stenosis with substantial comorbidity. We report the outcomes of 18 high-risk patients who received BAV within 180 days before AVR from November 1993 through December 2011. Their median age was 78 years (range, 51-93 yr), and there were 11 men (61%). The pre-BAV median calculated Society of Thoracic Surgeons Predicted Risk of Mortality (STS PROM) was 18.3% (range, 9.4%-50.7%). Preoperative left ventricular ejection fraction measured a median of 0.23 (range, 0.05-0.68), and the median aortic valve area index was 0.4 cm(2)/m(2) (range, 0.2-0.7 cm(2)/m(2)). The median interval from BAV to AVR was 28 days (range, 1-155 d). There were no strokes or deaths after BAV; however, 4 patients (22%) required mechanical circulatory support, 3 (17%) required femoral artery operation, and 1 (6%) developed severe aortic valve regurgitation. After BAV, the median STS PROM fell to 9.1% (range, 2.6%-25.7%) (compared with pre-BAV, P <0.001). Echocardiography before AVR showed that the median left ventricular ejection fraction had improved to 0.35 (range, 0.15-0.66), and the aortic valve area index to 0.5 cm(2)/m(2) (range, 0.3-0.7 cm(2)/m(2)) (compared with pre-BAV, both P <0.05). All patients received AVR. Operative death occurred in 2 patients (11%), and combined operative death and morbidity in 7 patients (39%). Staged BAV substantially reduces the operative risk associated with AVR in selected patients.
Предметные рубрики MeSH
AgedAortic ValveAortic Valve InsufficiencyAortic Valve StenosisBalloon ValvuloplastyEchocardiographyFemaleHeart Valve Prosthesis ImplantationHumansMaleOutcome Assessment, Health CarePostoperative ComplicationsPreoperative CareRetrospective StudiesRisk AdjustmentRisk FactorsSeverity of Illness IndexTime FactorsUnited StatesVentricular Function, Left