Treatment of aortic stenosis with a self-expanding transcatheter valve: the International Multi-centre ADVANCE Study.
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Linke Axel, Wenaweser Peter, Gerckens Ulrich, Tamburino Corrado, Bosmans Johan, Bleiziffer Sabine, Blackman Daniel, Schäfer Ulrich, Müller Ralf, Sievert Horst, Søndergaard Lars, Klugmann Silvio, Hoffmann Rainer, Tchétché Didier, Colombo Antonio, Legrand Victor M, Bedogni Francesco, lePrince Pascal, Schuler Gerhard, Mazzitelli Domenico, Eftychiou Christos, Frerker Christian, Boekstegers Peter, Windecker Stephan, Mohr Friedrich-Wilhelm, Woitek Felix, Lange Rüdiger, Bauernschmitt Robert, Brecker Stephen, ADVANCE study Investigators
Аннотация
METHODS AND RESULTS: Patients with severe aortic stenosis at a higher surgical risk in whom implantation of the CoreValve System was decided by the Heart Team were included. Endpoints were a composite of major adverse cardiovascular and cerebrovascular events (MACCE; all-cause mortality, myocardial infarction, stroke, or reintervention) and mortality at 30 days and 1 year. Endpoint-related events were independently adjudicated based on Valve Academic Research Consortium definitions. A total of 1015 patients [mean logistic EuroSCORE 19.4 ± 12.3% [median (Q1,Q3), 16.0% (10.3, 25.3%)], age 81 ± 6 years] were enrolled. Implantation of the CoreValve System led to a significant improvement in haemodynamics and an increase in the effective aortic valve orifice area. At 30 days, the MACCE rate was 8.0% (95% CI: 6.3-9.7%), all-cause mortality was 4.5% (3.2-5.8%), cardiovascular mortality was 3.4% (2.3-4.6%), and the rate of stroke was 3.0% (2.0-4.1%). The life-threatening or disabling bleeding rate was 4.0% (2.8-6.3%). The 12-month rates of MACCE, all-cause mortality, cardiovascular mortality, and stroke were 21.2% (18.4-24.1%), 17.9% (15.2-20.5%), 11.7% (9.4-14.1%), and 4.5% (2.9-6.1%), respectively. The 12-month rates of all-cause mortality were 11.1, 16.5, and 23.6% among patients with a logistic EuroSCORE ≤10%, EuroSCORE 10-20%, and EuroSCORE >20% (P< 0.05), respectively.
CONCLUSION: The ADVANCE study demonstrates the safety and effectiveness of the CoreValve System with low mortality and stroke rates in higher risk real-world patients with severe aortic stenosis.