DOI 10.1097/imi.0000000000000018
Outcome of patients treated with Engager transapical aortic valve implantation: one-year results of the feasibility study.
Аннотация
OBJECTIVE
The aim of this study was to investigate the short-term and midterm outcome of the Engager transcatheter aortic valve implantation (TAVI) system, a transapical self-expanding valve device with anatomic orientation.
METHODS
Transapical aortic valve implantation with the Engager valve prosthesis was performed in 10 patients. Endpoints were defined according to the Valve Academic Research Consortium recommendations for reporting outcomes of TAVI in clinical trials. Follow-up has been completed after 30 days and 1 year.
RESULTS
All patients underwent the implantation procedure successfully. No device-related or delivery system-related complications were observed. One patient died of non-device-related reasons at postoperative day 23 in multiorgan failure. At 30-day follow-up, no more than mild transvalvular and paravalvular aortic regurgitation were seen. After 1 year, no transvalvular regurgitation was observed as assessed by transthoracic echocardiography. None of the patients had more than mild paravalvular leakage. The mean ± SD gradient was 15.3 ± 4.2 mm Hg. New York Heart Association class decreased one degree in mean and sustained until 1-year follow-up. No more patients died until 1-year follow-up.
CONCLUSIONS
Application of the Engager TAVI system is safe and reliable. Prosthesis deployment in an anatomically correct position was facilitated by the design of the valve prosthesis and successful in all patients. No device-related or delivery system-related complications occurred. Procedural, short-term, and midterm results up to 1 year concerning the aortic valve performance are promising, with stable mean gradients and low rates of even mild regurgitation.