JACC. Clinical electrophysiology · 2023

Frequency Domain Analysis of Endocardial Electrograms for Detection of Nontransmural Myocardial Fibrosis in Nonischemic Cardiomyopathy.

СтатьяПоддержка правительства СШАПоддержка исследования: вне правительства СШАКомментарийНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Whitaker John, Baum Taylor E, Qian Pierre, Prassl Anton J, Plank Gernot, Blankstein Ron, Cochet Hubert, Sauer William H, Bishop Martin J, Tedrow Usha

Аннотация

BACKGROUND: Voltage mapping in nonischemic cardiomyopathy can fail to identify midmyocardial substrate for ventricular arrhythmias, an important cause of ablation failure.

OBJECTIVES: The aim of this study was to assess whether frequency domain analysis of endocardial left ventricular electrograms (EGMs) can better predict the presence of midmyocardial fibrosis (MMF) compared with voltage amplitude.

METHODS: Nonischemic cardiomyopathy patients undergoing ventricular tachycardia ablation with registered preprocedural cardiac computed tomography and late iodine enhancement were included. Presence of fibrosis at each EGM site was assessed. Bipolar and unipolar EGMs were transformed to the frequency domain using multitaper spectral analysis. Singular value decomposition of the EGM frequency spectrum was used within a supervised machine learning process to select features to predict the presence of MMF and compare against predictions using voltage amplitude.

RESULTS: Thirteen patients were included (median age 57 years [IQR: 28-73 years], median ejection fraction 40% [IQR: 15%-57%]). A total of 6,015 EGM pairs were processed: 2,459 EGM pairs in MMF areas and 3,556 EGM pairs in non-MMF areas. Supervised classifiers were trained with stratified k-fold cross-validation within patients. The distribution of mean area under the curve metrics using frequency features, f, was significantly greater than voltage feature area under the curve metrics, v, (mean f = 0.841 [95% CI: 0.789-0.884] vs mean v = 0.591 [95% CI: 0.530-0.658]; P < 0.001), indicating that frequency-trained classifiers better predicted the presence of MMF.

CONCLUSIONS: These data indicate the promising discriminatory value of endocardial EGM frequency content in the assessment of concealed myocardial substrate. Further studies are needed to investigate the importance of the specific frequency features identified.