Outcomes of single-port robotic ureteral reconstruction using the da Vinci SP® system.

Heo Ji Eun, Kang Sung Ku, Lee Jongsoo, Koh Donghoon, Kim Min Seok, Lee Yong Seung, Ham Won Sik, Jang Won Sik

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: The da Vinci SP® robotic system enables three double-jointed wristed instruments and a fully wristed three-dimensional camera to be placed through a single port. This study presents our experience with robot-assisted ureteral reconstruction using the SP system and reports its outcomes.

MATERIALS AND

METHODS

Between December 2018 and April 2022, a single surgeon performed robotic ureteral reconstruction using the SP system in 39 patients: 18 underwent pyeloplasty and 21 received ureteral reimplantation. Demographic and perioperative patient data were collected and analyzed. Radiographic and symptomatic improvements were assessed 3 months after surgery.

RESULTS

In pyeloplasty group, 12 patients (66.7%) were female and two patients (11.1%) had undergone previous surgery for ureteral obstruction. The median operative time was 152 minutes, the median blood loss was 8 mL, and the median length of stay in hospital was 3 days. There was one case of a complication involving postoperative percutaneous nephrostomy (PCN). In ureteral reimplantation group, 19 patients (90.5%) were female and ten patients (47.6%) had undergone gynecological surgery that caused ureteral obstruction. The median operative time was 152 minutes, the median blood loss was 10 mL, and the median length of stay in hospital was 4 days. We observed one case of open conversion and two cases of complications (colonic serosal tearing and postoperative PCN after ileal ureter replacement). The radiographic results and symptoms successfully improved following both surgeries.

CONCLUSIONS

Despite adhesion-related complications, the SP system appears to be safe and effective for use in robot-assisted ureteral reconstruction.

Для цитирования: Heo Ji Eun, Kang Sung Ku, Lee Jongsoo, Koh Donghoon, Kim Min Seok, Lee Yong Seung, Ham Won Sik, Jang Won Sik. Outcomes of single-port robotic ureteral reconstruction using the da Vinci SP® system.. Investigative and clinical urology. 2023. DOI: 10.4111/icu.20230005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.