MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00464-023-10142-6

Медицинская библиотека · Surgical endoscopy · 2023

Simultaneous fluorescence imaging of bowel perfusion and ureter delineation using methylene blue: a demonstration in a porcine model.

Heuvelings Danique J I, Al-Difaie Zaid, Scheepers Max H M C, Okamoto Nariaki, Diana Michele, Stassen Laurents P S, Bouvy Nicole D, Al-Taher Mahdi

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Intraoperative near-infrared fluorescence imaging (NIRF) with preoperative optical dye administration is a promising technique for quick and easy intraoperative visualization of the ureter and for an improved, real-time assessment of intestinal perfusion. During colorectal surgery, there is a need for simultaneous non-invasive ureteral imaging and bowel perfusion assessment, using one single camera system. The purpose of this study is to investigate the feasibility of simultaneous intestinal perfusion and ureteral imaging using a single commercially available NIRF imaging system.

METHODS

Six Landrace pigs underwent laparotomy under general anesthesia in this experiment. An intravenous (IV) dose of 0.2 mg/kg indocyanine green (ICG) was given to assess bowel perfusion. Two pairs received a methylene blue (MB) iv injection of 0.75, 0.50 or 0.25 mg/kg respectively to investigate ureteral visualization. Quest Spectrum Fluorescence Camera (Quest Medical Imaging, Middenmeer, The Netherlands) was used for NIRF imaging.

RESULTS

Ureter visualization and bowel perfusion under NIRF imaging was achieved in all animals. All ureters were visible after five to ten minutes and remained clearly visible until the end of every experiment (120-420 min). A mixed model analysis did not show any significant differences neither between the three groups nor over time. Importantly, we demonstrated that bowel perfusion could be visualized with methylene blue (MB) as well. We observed no interference between ICG and MB and a faster washout of MB.

CONCLUSION

We successfully demonstrated simultaneous fluorescence angiography with ICG and ureteral imaging with MB in the same surgical procedure, with the same commercially available NIRF imaging equipment. More importantly, we showed that the use MB is adequate for bowel perfusion assessment and ureter visualization with this NIRF imaging system. Besides, MB showed an earlier washout time, which can be clinical beneficial as a repeated dye injection may be necessary during a surgical procedure.

Для цитирования: Heuvelings Danique J I, Al-Difaie Zaid, Scheepers Max H M C, Okamoto Nariaki, Diana Michele, Stassen Laurents P S, Bouvy Nicole D, Al-Taher Mahdi. Simultaneous fluorescence imaging of bowel perfusion and ureter delineation using methylene blue: a demonstration in a porcine model.. Surgical endoscopy. 2023. DOI: 10.1007/s00464-023-10142-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.