m+Medelevator.RU
← Поиск публикаций
Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2011

Prediction of fetal macrosomia: effect of sonographic fetal weight-estimation model and threshold used.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Melamed N, Yogev Y, Meizner I, Mashiach R, Pardo J, Ben-Haroush A

Аннотация

OBJECTIVE: To compare the accuracy of 21 sonographic fetal weight-estimation models and abdominal circumference (AC) as a single measure for the prediction of fetal macrosomia (> 4000 g) using either fixed or optimal model-specific thresholds.

METHODS: A total of 4765 sonographic weight estimations performed within 3 days prior to delivery were analyzed. The predictive accuracy of 21 published sonographic fetal weight-estimation models was calculated using three different thresholds: a fixed threshold of 4000 g; a model-specific threshold obtained from the inflexion point of the receiver-operating characteristics (ROC) curve; and a model-specific threshold associated with the highest overall accuracy. Cluster analysis was used to determine whether a certain combination of fetal biometric indices is associated with a higher predictive accuracy than others.

RESULTS: For a fixed threshold of > 4000 g, there was considerable variation among the models in sensitivity (range, 13.6-98.5%) and specificity (range, 63.6-99.8%) for fetal macrosomia. Use of the threshold derived from the inflexion point of the ROC curve decreased the intermodel variation to a minimum (sensitivity, 84.4-91.4%; and specificity, 79.5-86.3%). Even when this optimal model-specific threshold was applied, models based on three to four biometric indices were more accurate than were models based on only two biometric indices or on AC as a single measure (P=0.03).

CONCLUSIONS: Sonographic fetal weight-estimation models based on three to four biometric indices appear to be more accurate than are models based on two indices or on AC as a single measure, for the diagnosis of macrosomia. In these cases, the use of an optimal, model-specific threshold is associated with a higher degree of accuracy than is the uniform use of a fixed threshold of an estimated weight of > 4000 g.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты