MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjopen-2017-016909

Медицинская библиотека · BMJ open · 2017

APpropriAteness of percutaneous Coronary interventions in patients with ischaemic HEart disease in Italy: the APACHE pilot study.

Leonardi Sergio, Marino Marcello, Crimi Gabriele, Maiorana Florinda, Rizzotti Diego, Lettieri Corrado, Bettari Luca, Zuccari Marco, Sganzerla Paolo, Tresoldi Simone, Adamo Marianna, Ghiringhelli Sergio, Sponzilli Carlo, Pasquetto Giampaolo, Pavei Andrea, Pedon Luigi, Bassan Luciano, Bollati Mario, Camisasca Paola, Trabattoni Daniela, Brancati Marta, Poli Arnaldo, Panciroli Claudio, Lettino Maddalena, Tarelli Giuseppe, Tarantini Giuseppe, De Luca Leonardo, Varbella Ferdinando, Musumeci Giuseppe, De Servi Stefano

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To first explore in Italy appropriateness of indication, adherence to guideline recommendations and mode of selection for coronary revascularisation.

DESIGN

Retrospective, pilot study.

SETTING

22 percutaneous coronary intervention (PCI)-performing hospitals (20 patients per site), 13 (59%) with on-site cardiac surgery.

PARTICIPANTS

440 patients who received PCI for stable coronary artery disease (CAD) or non-ST elevation acute coronary syndrome were independently selected in a 4:1 ratio with half diabetics.

PRIMARY AND SECONDARY OUTCOME MEASURES: Proportion of patients who received appropriate PCI using validated appropriate use scores (ie, AUS≥7). Also, in patients with stable CAD, we examined adherence to the following European Society of Cardiology recommendations: (A) per cent of patients with complex coronary anatomy treated after heart team discussion; (B) per cent of fractional flow reserve-guided PCI for borderline stenoses in patients without documented ischaemia; (C) per cent of patients receiving guideline-directed medical therapy at the time of PCI as well as use of provocative test of ischaemia according to pretest probability (PTP) of CAD.

RESULTS

Of the 401 mappable PCIs (91%), 38.7% (95% CI 33.9 to 43.6) were classified as appropriate, 47.6% (95% CI 42.7 to 52.6) as uncertain and 13.7% (95% CI 10.5% to 17.5%) as inappropriate. Median PTP in patients with stable CAD without known coronary anatomy was 69% (78% intermediate PTP, 22% high PTP). Ischaemia testing use was similar (p=0.71) in patients with intermediate (n=140, 63%) and with high PTP (n=40, 66%). In patients with stable CAD (n=352) guideline adherence to the three recommendations explored was: (A) 11%; (B) 25%; (C) 23%. AUS was higher in patients evaluated by the heart team as compared with patients who were not (7 (6.8) vs 5 (4.7); p=0.001).

CONCLUSIONS

Use of heart team approaches and adherence to guideline recommendations on coronary revascularisation in a real-world setting is limited. This pilot study documents the feasibility of measuring appropriateness and guideline adherence in clinical practice and identifies substantial opportunities for quality improvement.

TRIAL REGISTRATION NUMBER: NCT02748603.

Для цитирования: Leonardi Sergio, Marino Marcello, Crimi Gabriele, Maiorana Florinda, Rizzotti Diego, Lettieri Corrado, Bettari Luca, Zuccari Marco, Sganzerla Paolo, Tresoldi Simone, Adamo Marianna, Ghiringhelli Sergio, Sponzilli Carlo, Pasquetto Giampaolo, Pavei Andrea, Pedon Luigi, Bassan Luciano, Bollati Mario, Camisasca Paola, Trabattoni Daniela, Brancati Marta, Poli Arnaldo, Panciroli Claudio, Lettino Maddalena, Tarelli Giuseppe, Tarantini Giuseppe, De Luca Leonardo, Varbella Ferdinando, Musumeci Giuseppe, De Servi Stefano. APpropriAteness of percutaneous Coronary interventions in patients with ischaemic HEart disease in Italy: the APACHE pilot study.. BMJ open. 2017. DOI: 10.1136/bmjopen-2017-016909.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.