MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12872-025-05243-0

Медицинская библиотека · BMC cardiovascular disorders · 2025

Optical coherence tomography guided additional Noevas bioresorbable vascular scaffold in the treatment of iatrogenic coronary artery dissection: a case report.

Zhou Dengshuang, Huang Bobin, Chen Jue, You Qiong, Mo Hailiang, Wu Zijun, Lin Yubiao, Chen Lujun, Fan Junyu, Deng Wenyu, Wu Keng

СтатьяКлинический случайПеревод в очереди

Аннотация

BACKGROUND

Iatrogenic coronary artery dissection is a potential complication during percutaneous coronary bioresorbable vascular scaffolds placement. We report that significant dissection occurred during post-expansion of the left circumflex branch bioresorbable vascular scaffolds to attach it to the wall. Additional resorbable stents successfully covered the dissection without blood flow restriction.

CASEREPORT: The patient was a 49-year-old male with refusing intracoronary metal stents and was diagnosed with stable angina pectoris and type 2 diabetes. Coronary angiography showed serious lesions in three vessels. A Noevas stent was had placed in the proximal segment of the anterior descending branch. Unfortunately a type-D dissection occurred during post-dilatation after the second scaffold was placed in the proximal of the circumflex branch. A third scaffold was inserted to cover the dissection and optical coherence tomography reexamination showed good apposition. After 6 months of coronary angiography, optical coherence tomography examination showed no deterioration of the circumflex branch dissection, and the proximal intimal hyperplasia in the proximal scaffold was 95%. Scoring balloon and drug balloon dilatation were successfully performed, and right coronary artery dilatation with drug coated balloon was performed. The patient had no symptoms of chest pain after 2 years of follow-up.

CONCLUSION

Additional bioresorbable vascular scaffold coverage of coronary type-D dissection with the help of imaging tools may be a practical strategy when patients selcet for coronary metal-less implantation. Furthermore, imaging review is recommended especially for diabetics.

Для цитирования: Zhou Dengshuang, Huang Bobin, Chen Jue, You Qiong, Mo Hailiang, Wu Zijun, Lin Yubiao, Chen Lujun, Fan Junyu, Deng Wenyu, Wu Keng. Optical coherence tomography guided additional Noevas bioresorbable vascular scaffold in the treatment of iatrogenic coronary artery dissection: a case report.. BMC cardiovascular disorders. 2025. DOI: 10.1186/s12872-025-05243-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.