MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3171/jns.2004.100.5.0960

Медицинская библиотека · Journal of neurosurgery · 2004

Monitoring and preventing blood flow insufficiency due to clip rotation after the treatment of internal carotid artery aneurysms.

Sakuma Jun, Suzuki Kyouichi, Sasaki Tatsuya, Matsumoto Masato, Oinuma Masahiro, Kawakami Masahisa, Itakura Takeshi, Kodama Namio

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

The authors report a case in which anterior choroidal artery (AChA) blood flow insufficiency due to aneurysm clip rotation was detected intraoperatively by motor evoked potential (MEP) monitoring and ischemia was successfully avoided. The patient had an incidentally discovered aneurysm for which occlusion of its neck was performed through a standard frontotemporal craniotomy without changing the MEP amplitude. After it was confirmed that the surrounding arteries were not stenotic, the brain retractor on the frontal lobe was released; MEP amplitude subsequently decreased. Rotation of the clip toward the frontal base by repositioning of the frontal lobe caused the AChA stenosis at the origin of its branches. On reorienting the clip toward the frontal lobe, the AChA stenosis was released and MEP amplitude recovered. To prevent repeated clip rotation, a large amount of gelatin (Spongel) was inserted between the frontal base and the clip. The authors confirmed that clip rotation did not occur after repositioning of the frontal lobe. Motor evoked potential amplitude was maintained until dural closure. Postoperatively, the patient demonstrated no neurological deficit and there was no newly developed low-density area on computerized tomography scans.

Для цитирования: Sakuma Jun, Suzuki Kyouichi, Sasaki Tatsuya, Matsumoto Masato, Oinuma Masahiro, Kawakami Masahisa, Itakura Takeshi, Kodama Namio. Monitoring and preventing blood flow insufficiency due to clip rotation after the treatment of internal carotid artery aneurysms.. Journal of neurosurgery. 2004. DOI: 10.3171/jns.2004.100.5.0960.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.