Transcranial Doppler and near-infrared spectroscopy can evaluate the hemodynamic effect of carotid artery occlusion.

Клиническое исследованиеКонтролируемое клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Vernieri Fabrizio, Tibuzzi Francesco, Pasqualetti Patrizio, Rosato Nicola, Passarelli Francesco, Rossini Paolo Maria, Silvestrini Mauro

Аннотация

BACKGROUND AND PURPOSE: Cerebral hemodynamic and metabolic changes can compensate for the decrease in cerebral blood flow occurring in patients with carotid occlusive disease. At present, a complete assessment of the cerebral adaptive status is only possible with positron-emission tomography. Near-infrared spectroscopy (NIRS) is a noninvasive technique that, providing a real time assessment of fluctuations in cerebral hemoglobin, has been used to estimate the cerebral blood volume and to measure cerebral vasomotor reactivity (VMR). Moreover, NIRS technology, by allowing the absolute measurement of absorption and scattering coefficients of brain, can determine the oxyhemoglobin and deoxyhemoglobin concentrations in situ in the blood stream.

METHODS: In order to evaluate different aspects of the cerebral hemodynamic status, 27 subjects with symptomatic and asymptomatic carotid artery occlusion and 30 healthy subjects underwent a simultaneous examination by means of transcranial Doppler (TCD), able to reliably detect collateral circulation and VMR, and NIRS at rest condition and during CO2 reactivity test.

RESULTS: The main finding of this study was the demonstration of a difference between asymptomatic and symptomatic patients in terms of mean flow velocity increase (52.4% versus 21.0%; P<0.001) estimated by TCD and of hemoglobin saturation increase measured by NIRS (6.8% versus 3.8%; P=0.015).

CONCLUSIONS: The opportunity to perform NIRS and TCD simultaneously provides useful information about both hemodynamic and metabolic cerebral adaptive status in patients with occlusive disease in a simple, noninvasive, and reliable way.