Shoemaker Leena N, Matern Tyson, Kamar Farah, St Lawrence Keith, Ortega-Gutierrez Santiago, Zanaty Mario, Shoemaker J Kevin
Аннотация
The lack of direct measures of brain blood pressure (BBP) has severely restricted understanding of cerebral pressure-flow relationships and their control. We sought to evaluate the feasibility of directly measuring BBP and its pulsatility between the aorta and middle cerebral artery (MCA) during elective endovascular surgical procedures. We report five case studies (four female, 61 ± 13 yr; means ± SD) of patients undergoing cerebrovascular interventional procedures for aneurysm and stenoses, using direct BBP measures with the COMET 2 pressure guidewire system (Boston Scientific). Patients were supine, intubated, and under anesthesia. The sensor wire was inserted via the femoral artery, measuring, as feasible, blood pressure (BP) in the aorta to MCA vascular segments, referenced to the radial artery BP waveform (arterial catheter). Mean arterial pressure varied between the radial (80 ± 18 mmHg), internal carotid artery (ICA; 70 ± 25 mmHg), and MCA (62 ± 29 mmHg), and marked interindividual heterogeneity was observed. Pulse pressure was higher in the radial artery (68 ± 23 mmHg) compared with the intracranial ICA (ICAi; 43 ± 29 mmHg) and MCA (M1; 25 ± 12 mmHg) segments. Direct measures of BBP in humans are feasible in this interventional surgery model. Although limited by the small sample size, the results suggest a heterogenous pattern of change between systemic and brain measures of blood pressure and pulse pressure.NEW & NOTEWORTHY We explored the feasibility of making direct measures of blood pressure in the large arteries at the base of the brain in humans. Measures were made with an optical sensor positioned in the aorta, common carotid, internal carotid artery external to the cranium, internal carotid artery within the cranium, and/or middle cerebral artery (MCA), M1 segment. Measures varied across individuals, as did the pressure gradient from systemic pressures to those in the MCA.