DOI 10.1016/j.jdiacomp.2022.108314
Effects of flash glucose monitoring on glycemic control in participants with diabetes mellitus: A meta-analysis of randomized controlled trials.
Аннотация
BACKGROUND
With the introduction of flash glucose monitoring (FGM) into the international market in 2014, academics worldwide are exploring whether this device improves glycemic control in participants with diabetes mellitus.
OBJECTIVE
A study was conducted in which participants were evaluated to determine the effect of FGM on glycemic control.
METHODS
From inception to April 9, 2022, we searched the Cochrane Library, PubMed, SinoMed, Embase, Web of Science, MEDLINE, CNKI, Wan Fang Data, and VIP databases to collect randomized controlled trials (RCTs) related to the effect of FGM on glycemic control in participants with diabetes mellitus. Outcomes included glycated hemoglobin, the occurrence of hypoglycemic events, fasting plasma glucose (FPG), and 2-h postprandial glucose (2hPG) levels. The statistical analysis was performed using R 4.1.3 software.
RESULTS
We included 19 studies involving 2013 participants, all of which were RCTs. Meta-analysis results revealed that compared to self-monitoring of blood glucose (SMBG), FGM significantly reduced glycated hemoglobin levels in participants with type 2 diabetes mellitus [mean difference = -0.74 [95 % CI-1.16, -0.32], P < 0.01] and type 1 diabetes mellitus combined with type 2 diabetes mellitus [mean difference = -1.14 [95 % CI-3.14, 0.87], P < 0.01], with a greater effect in participants aged ≤65 years with type 2 diabetes mellitus (mean difference = -1.38 [95 % CI-2.05, -0.72], P < 0.01). However, there was no effect of FGM on the improvement of glycated hemoglobin levels in patients with type 1 diabetes mellitus [P = 0.45]. Furthermore, fasting plasma glucose levels and 2-h postprandial glucose levels were significantly lower in FGM than SMBG, and the number of hypoglycemic events was also significantly lower.
CONCLUSION
Comparing SMBG with FGM indicated that FGM improves fasting plasma glucose levels, 2-h postprandial glucose levels, and glycated hemoglobin levels, and it reduces the number of hypoglycemic events.