MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00004424-199409000-00005

Медицинская библиотека · Investigative radiology · 1994

Prediction of change in mitral valve area after mitral balloon commissurotomy using cine computed tomography.

White M L, Grover-McKay M, Weiss R M, Vandenberg B F, Burns T L, Winniford M D, Stanford W, McKay C R

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

RATIONALE AND

OBJECTIVES

Mitral balloon commissurotomy (MBC) can successfully increase the mitral valve area (MVA) in mitral stenosis, but the outcome is variable. In multicenter studies, qualitative echocardiographic scores obtained before MBC are only weakly predictive of the increase in MVA after MBC.

METHODS

To evaluate whether the change in MVA after MBC can be predicted by evaluating mitral valve morphology using cine computed tomography (CT), we studied 12 women with mitral stenosis and 11 female control subjects.

RESULTS

In the patients with mitral stenosis, MVA increased from 1.13 +/- 0.24 to 1.93 +/- 0.56 cm2 (P < .0001) after MBC. A standard echocardiographic score assessment of mitral valve morphology before MBC was not associated with the change in MVA after MBC in these patients (P > .20). However, the total mitral valve morphology score evaluated by cine computed tomography was strongly associated with the change in MVA after MBC (r = -.87; P < .0005). In addition, the individual morphologic characteristics of mitral valve mobility (P < .0025), leaflet thickness (P < .05), and subvalvular disease (P < .05) were significant predictors of the change in MVA after MBC.

CONCLUSION

Cine computed tomography may be useful for predicting immediate increases in MVA in patients after MBC and may be helpful for preoperative assessment of these patients.

Для цитирования: White M L, Grover-McKay M, Weiss R M, Vandenberg B F, Burns T L, Winniford M D, Stanford W, McKay C R. Prediction of change in mitral valve area after mitral balloon commissurotomy using cine computed tomography.. Investigative radiology. 1994. DOI: 10.1097/00004424-199409000-00005.