Drug-eluting bioresorbable scaffolds in cardiovascular disease, peripheral artery and gastrointestinal fields: a clinical update.
СтатьяОбзорНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kawashima Hideyuki, Ono Masafumi, Kogame Norihiro, Takahashi Kuniaki, Chang Chun-Chin, Hara Hironori, Gao Chao, Wang Rutao, Tomaniak Mariusz, Modolo Rodrigo, Wykrzykowska Joanna J, De Winter Robbert J, Sharif Faisal, Serruys Patrick W, Onuma Yoshinobu
Аннотация
INTRODUCTION: The technology of bioresorbable scaffold (BRS) spread out after the success of the first-in-man trials of the Absorb. However, the randomized trials demonstrated that major adverse cardiac events and scaffold thrombosis rates of the first-generation Absorb were higher than those of the metallic everolimus-eluting stent. To overcome the shortcoming of the firstly commercialized Absorb, novel technologies have been developed.
AREAS COVERED: In this review, we overviewed the field of BRS in the treatment of coronary, peripheral artery and gastrointestinal fields. To date, 10 BRS devices developed by 6 manufacturers have acquired the CE mark in coronary artery disease. Currently 8 BRS are in clinical trial phase, whereas 7 BRS are in preclinical assessment phase. Most new-generation devices have a strut thickness of less than 100 μm. However, late favorable outcome might be achieved not only by device refinement but also by a proper technique of implantation using intra vascular imaging guidance, as well as with a careful patient and lesion selection.
EXPERT OPINION: New-generation BRS will be soon tested in the clinical arena to demonstrate improved acute and long-term of safety and efficacy.
AREAS COVERED: In this review, we overviewed the field of BRS in the treatment of coronary, peripheral artery and gastrointestinal fields. To date, 10 BRS devices developed by 6 manufacturers have acquired the CE mark in coronary artery disease. Currently 8 BRS are in clinical trial phase, whereas 7 BRS are in preclinical assessment phase. Most new-generation devices have a strut thickness of less than 100 μm. However, late favorable outcome might be achieved not only by device refinement but also by a proper technique of implantation using intra vascular imaging guidance, as well as with a careful patient and lesion selection.
EXPERT OPINION: New-generation BRS will be soon tested in the clinical arena to demonstrate improved acute and long-term of safety and efficacy.