MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10439-020-02532-x

Медицинская библиотека · Annals of biomedical engineering · 2020

Influence of Patient-Specific Characteristics on Transcatheter Heart Valve Neo-Sinus Flow: An In Silico Study.

Singh-Gryzbon Shelly, Ncho Beatrice, Sadri Vahid, Bhat Sanchita S, Kollapaneni Sai S, Balakumar Dharani, Wei Zhenglun A, Ruile Philipp, Neumann Franz-Joseph, Blanke Philipp, Yoganathan Ajit P

СтатьяПеревод пока не подготовлен

Аннотация

Thrombosis in post-transcatheter aortic valve replacement (TAVR) patients has been correlated with flow stasis in the neo-sinus. This study investigated the effect of the post-TAVR geometry on flow stasis. Computed tomography angiography of 155 patients who underwent TAVR using a SAPIEN 3 were used to identify patients with and without thrombosis, and quantify thrombus volumes. Six patients with 23-mm SAPIEN 3 valves were then selected from the cohort and used to create patient-specific post-TAVR computational fluid dynamic models. Regions of flow stasis (%Volstasis, velocities below 0.05 m/s) were identified. The results showed that all post-TAVR anatomical measurements were significantly different in patients with and without thrombus, but only sinus diameter had a linear correlation with thrombus volume (r = 0.471, p = 0.008). A linear correlation was observed between %Volstasis and thrombus volume (r = 0.821, p = 0.007). The combination of anatomy and valve deployment created a unique geometry in each patient, which when combined with patient-specific cardiac output, resulted in distinct flow patterns. While parametric studies have shown individual anatomical or deployment metrics may relate to flow stasis, the combined effects of these metrics potentially contributes to the biomechanical environment promoting thrombosis, therefore hemodynamic studies of TAVR should account for these patient-specific factors.

Для цитирования: Singh-Gryzbon Shelly, Ncho Beatrice, Sadri Vahid, Bhat Sanchita S, Kollapaneni Sai S, Balakumar Dharani, Wei Zhenglun A, Ruile Philipp, Neumann Franz-Joseph, Blanke Philipp, Yoganathan Ajit P. Influence of Patient-Specific Characteristics on Transcatheter Heart Valve Neo-Sinus Flow: An In Silico Study.. Annals of biomedical engineering. 2020. DOI: 10.1007/s10439-020-02532-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.