m+Medelevator.RU
← Поиск публикаций
Medical science monitor : international medical journal of experimental and clinical research · 2020

Effects of a Matrix Metalloproteinase Inhibitor-Eluting Stent on In-Stent Restenosis.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Song Jian-Bo, Shen Jing, Fan Jun, Zhang Zhe, Yi Zheng-Jia, Bai Shuo, Mu Xiao-Lin, Xiao Liang

Аннотация

BACKGROUND The aim of this study was to compare changes in the extracellular matrix after implantation of a stent that elutes a matrix metalloproteinase (MMP) inhibitor (GM6001); and to determine the effects of the GM6001-eluting stent upon prevention of in-stent restenosis (ISR). MATERIAL AND METHODS We included 48 Guangxi Bama mini-pigs in this study. A GM6001-eluting stent was placed in one iliac artery and a stent that did not elute GM6001 was placed in the contralateral iliac artery. The iliac arteries were removed at 6 hours as well as 1, 7, 14, 56, 84, and 336 days after stent placement. Arteries were analyzed for morphometry, gelatinase content, different phenotypes of vascular smooth muscle cells (VSMCs), collagen content, apoptotic rate, and cell density. RESULTS The vascular lumen areas of the GM6001 group were significantly increased and the neointimal areas were significantly reduced compared with the control group from the 7 days to the 336 days. In the 2 groups, expression of MMP-2 and MMP-9 peaked simultaneously, but GM6001-eluting stents inhibited expression of MMP-2 and MMP-9 in the vascular media and neointima (especially around the struts) significantly. In the GM6001 group, expression of tissue inhibitor of matrix metalloproteinase (TIMP)-1, TIMP-2, myosin heavy chain 10 (MYH-10, marker of the proliferative phenotype of VSMCs), collagen content, percentage of apoptotic cells, and cell density were also decreased significantly compared with those in the control group. CONCLUSIONS Use of GM6001-eluting stents resulted in persistent and potent inhibition of intimal hyperplasia, an increase in luminal area, and no obvious thrombosis in the arteries of the mini-pigs.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты