Cut-off value of strut-vessel distance for the resolution of acute incomplete stent apposition in the early phase using serial optical coherence tomography after cobalt-chromium everolimus-eluting stent implantation.

Клиническое исследованиеСтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Oda Hideto, Itoh Tomonori, Sasaki Wataru, Uchimura Yohei, Taguchi Yuya, Kaneko Kyosuke, Sakamoto Tsubasa, Goto Iwao, Sakuma Masafumi, Ishida Masaru, Kikuchi Tatsuo, Terashita Daisuke, Otake Hiromasa, Morino Yoshihiro, Shinke Toshiro

Аннотация

OBJECTIVE: The purpose of this study was to identify a cut-off value to predict the resolution of incomplete-stent-apposition (ISA) after cobalt-chromium everolimus-eluting stent (CoCr-EES) implantation at early follow-up.

BACKGROUND: To date, appropriate stent apposition at the acute period using intracoronary imaging has been recommended because persistent ISA is considered to be a risk factor for stent thrombosis. We examined the indices for resolving acute ISA. In particular, we determined the cut-off value for strut vessel distance (SV-distance) as visualized by optical coherence tomography (OCT) at 8 months after CoCr-EES implantation. However, the cut-off value of SV-distance for the earlier resolution of ISA is unclear.

METHODS: A total of 95 cases and 103 stents were registered in the MECHANISM Elective substudy. The SV-distance was measured at the deepest site of the target malapposition and every 1 mm from the proximal edge to the distal edge of the mal-apposed area using OCT. Cut-off values for ISA resolution at 1 and 3 months were estimated by SV-distance using receiver operating characteristic analysis.

RESULTS: The total number of analyzed struts was 14,418 at the 1-month follow-up and 11,986 at the 3-month follow-up. The optimal SV-distance cut-off values just after stent implantation to predict ISA resolution were 185 µm at the 1-month follow-up and 195 μm at the 3-month follow-up.

CONCLUSION: For resolution of ISA, SV-distance cut-off values of 185 µm at 1 month postimplantation and 195 μm at 3 months postimplantation can be used as the index of endpoint of the percutaneous coronary intervention.