OBJECTIVES

To evaluate our experience and short term surgical outcomes between two robotic systems.

METHODS

The present study retrospectively analyzed 38 cases, who underwent robotic adrenalectomy between 2012-2019 at our center. The patients were divided into Group Si (n=11) and Group Xi (n=27), and the results of these two groups were compared.

RESULTS

Demographic characteristics of both groups were similar between two groups. While, 42% of the patients had Cushing syndrome, 22% had Pheochromocytoma and 22% had Conn syndrome in the Xi group, 72% of the patients were non-secreting adrenocortical adenoma in Si group (p=0.005). The mean docking time in Group Xi was shorter than Si group (p=0.027). Console and total operation times were similar in both groups (p=0.312 and p=0.424; respectively). The intraoperative complication rate (p=0.500) and hospital stay (3.2±1.0 vs. 2.52±1.42 days, respectively, p = 0.077) were similar in both groups. Postoperative 4th and 12th hour Visual Analog Scale (VAS) scores were similar (p=0.213 and p=0.857; respectively). The average cost of robotic consumables was $210 higher in Xi group (p=0.495).

CONCLUSION

Our study shows that; the Xi robotic system is as safe as the Si system for adrenalectomy operations.

KEY WORDS: Adrenal gland surgery, Minimally invasive adrenalectomy, Robotic surgery.

Для цитирования: Aydın Hüsnü, Dural Ahmet Cem, Sahbaz Nuri Alper, Akarsu Cevher, Akbulut Sezer, Guzey Deniz, Ferahman Sina, Alis Halil, Karabulut Mehmet. Comparison of DaVinci Si and Xi robotic platforms for adrenal surgery. Effects on short term outcomes.. Annali italiani di chirurgia. 2023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.