MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7518/hxkq.2014.01.018

Медицинская библиотека · Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology · 2014

[In vitro study evaluating the effect of different subgingival root exposure methods and ferrule designs on fracture resistance of residual root].

Meng Qingfei, Chen Lijuan, Meng Jian

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the effect of different subgingival root exposure methods, namely, crown lengthening or forced eruption, and different ferrule lengths on fracture resistance of a residual root restored with a carbon fiber post-and-core system.

METHODS

Fifty-six extracted endodontically-treated mandibular first premolars were sectioned 1.0 mm coronal to the buccal cementoenamel junction. All the models were divided randomly into seven groups that each consist of eight roots. Group A was given non-ferrule as control. Simulated crown lengthening was performed for the dentin ferrule design in the cervical tooth structure for Groups B, C, and D with a ferrule length of 1.0, 2.0, and 3.0 mm, respectively. Simulated forced eruption was performed with a ferrule length of 1.0, 2.0, and 3.0 mm in the cervical tooth structure for Groups E, F, and G, respectively. After restoration with prefabricated carbon fiber post-and-core system, each specimen was embedded in a self-cured acrylic resin block from 2.0 mm apical to the margins of a cast Ni-Cr alloy crown, then loaded at 150 degrees from the long axis in a universal testing machine at a crosshead speed of 1.0 mm min(-1) until fracture. Data of failure loads and fracture mode were recorded and analyzed.

RESULTS

Mean failure loads for Groups A to G were (1.13 +/- 0.15), (1.27 +/- 0.18), (1.02 +/- 0.11), (1.05 +/- 0.12), (1.63 +/- 0.14), (1.92 +/- 0.19), and (1.93 +/- 0.15) kN, respectively. The effects of root exposure method and ferrule design differed significantly, and two factors exhibited significant interaction (F=33.396, P<0.0001). When the ferrule lengths were the same, fracture loads in the simulated forced eruption groups were significantly higher than those of the simulated crown lengthening groups (P<0.001). No statistical differences in fracture mode were observed among all groups (P=1.00).

CONCLUSION

More than 1.0 mm ferrule placement on the apical crown margin by using forced eruption significantly increases fracture resistance.

Для цитирования: Meng Qingfei, Chen Lijuan, Meng Jian. [In vitro study evaluating the effect of different subgingival root exposure methods and ferrule designs on fracture resistance of residual root].. Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology. 2014. DOI: 10.7518/hxkq.2014.01.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.