m+Medelevator.RU
← Поиск публикаций
The neuroradiology journal · 2020

Signal intensity pattern of the normal oculomotor nerve on contrast-enhanced 3D FLAIR at 3.0 T MRI.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sananmuang Thiparom, Boonsiriwattanakul Chanonporn, Panyaping Theeraphol

Аннотация

PURPOSE: The aim of this study was to depict the signal intensity pattern of the normal oculomotor nerve demonstrated on contrast-enhanced three-dimensional fluid-attenuated inversion recovery images.

MATERIALS AND METHODS: Eighty-one patients were included in the study. Contrast-enhanced three-dimensional fluid-attenuated inversion recovery images with magnetisation-prepared rapid acquisition were reconstructed and evaluated in the coronal plane. The signal intensity of the cisternal segment of the oculomotor nerve was graded into a visual scale of 1 to 5 as compared to the white matter, grey matter and the pituitary stalk. The signal intensity ratio of the oculomotor nerve was consequently measured.

RESULTS: By using the visual scale, more than half of the oculomotor nerves showed higher signal intensity than the grey matter signal on contrast-enhanced three-dimensional fluid-attenuated inversion recovery images (59.3-80.2%). It can demonstrate a signal intensity similar to the pituitary stalk (14.8%) by visualisation. None of them showed signal intensity equal to the normal white matter signal. By signal intensity measurement, the mean signal intensity ratio of oculomotor nerves to white matter equals 1.54±0.20 (95% confidence interval (CI) 1.51-1.57); mean signal intensity ratio to grey matter equals 1.16±0.15 (95% CI 1.14-1.18); mean signal intensity ratio to the pituitary stalk equals 0.68±0.10 (95% CI 0.64-0.70).

CONCLUSIONS: The normal oculomotor nerve visualised on contrast-enhanced three-dimensional fluid-attenuated inversion recovery images has a higher signal intensity than the white matter and may have a signal intensity similar to the grey matter or the pituitary stalk. The high signal intensity of the oculomotor nerve in contrast-enhanced three-dimensional fluid-attenuated inversion recovery should not be misinterpreted as a pathology.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты