MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/00045632211008923

Медицинская библиотека · Annals of clinical biochemistry · 2021

An LC-MS/MS assay for analysis of equilibrium angiotensin II in human serum.

Bernstone Laura, Adaway Joanne E, Keevil Brian G

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The current first-line screening test for primary hyperaldosteronism is the plasma aldosterone:renin ratio; however, renin assays have several disadvantages and the ARR is affected by medications and physiological factors. Angiotensin II is a key biologically active hormone in the renin-angiotensin-aldosterone system. It has been suggested that measurement of equilibrium levels of this peptide, involving an in vitro incubation of serum prior to analysis, may provide a better marker of renin-angiotensin-aldosterone system activity than renin.

METHODS

An eqAng II LC-MS/MS assay was developed, optimized and validated. Serum samples were incubated at 37°C for 45 min prior to stabilization with cold EDTA solution, solid phase extraction and LC-MS/MS analysis. Stability in whole blood and the effect of cryoactivation were assessed. For comparison to the current screening test, 150 anonymized patients' samples were analysed for eqAng II, renin activity and aldosterone (all by LC-MS/MS).

RESULTS

The assay had good precision, minimal bias and acceptable recovery. EqAng II did not change significantly when whole blood samples were stored for up to 72 h, and cryoactivation was only observed for pregnant patients. EqAng II was significantly correlated with renin, and the aldosterone:eqAng II ratio had a strong positive correlation with the aldosterone:renin ratio.

CONCLUSIONS

An LC-MS/MS assay for eqAng II has been developed which shows promise as an alternative screening test for primary hyperaldosteronism. Compared to renin assays, it is quicker, simpler and less likely to be affected by anti-hypertensive medications. Further clinical validation in hypertensive patients would be required prior to implementation.

Для цитирования: Bernstone Laura, Adaway Joanne E, Keevil Brian G. An LC-MS/MS assay for analysis of equilibrium angiotensin II in human serum.. Annals of clinical biochemistry. 2021. DOI: 10.1177/00045632211008923.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.