Global dispersion of right atrial repolarization in healthy pigs and patients.
Аннотация
OBJECTIVE
To investigate the feasibility of monophasic action potential (MAP) mapping using an electroanatomical mapping system (CARTO) in obtaining information on global dispersion of atrial repolarization and to evaluate the role of dispersion of repolarization in the genesis of paroxysmal atrial fibrillation (PAF).
METHODS AND
RESULTS
Right atrial MAPs were recorded from 53 +/- 18 sites in 10 healthy pigs and 33 +/- 21 sites in 6 patients with and 4 patients without history of PAF. In pigs, the global dispersions of activation time (AT), MAP duration and end of repolarization time (EOR), 70 +/- 8, 95 +/- 18 and 121 +/- 28 ms, respectively, were significantly greater than those among 10, 20 and 30 sites. In patients with PAF, the global dispersions of MAP duration and EOR (128 +/- 10 and 149 +/- 31 ms) were significantly greater than those in patients without PAF (84 +/- 10 and 91 +/- 17 ms).
CONCLUSION
MAP mapping using the CARTO system was feasible in experimental and clinical settings in obtaining information on global dispersion of atrial repolarization. The number of recording sites could significantly affect repolarization parameters. The dispersions of atrial repolarization were significantly greater in patients with PAF than those without, suggesting the involvement of an increased dispersion of repolarization in the genesis of PAF.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.