MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/bf02256115

Медицинская библиотека · Journal of biomedical science · 2003

Temperature regulates the arrhythmogenic activity of pulmonary vein cardiomyocytes.

Chen Yi-Jen, Chen Yao-Chang, Chan Paul, Lin Cheng-I, Chen Shih-Ann

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Temperature plays an important role in the electrophysiology of cardiomyocytes. Pulmonary veins (PVs) are known to initiate paroxysmal atrial fibrillation. The effects of temperature on the arrhythmogenic activity of rabbit single PV and atrial cardiomyocytes were assessed using the whole-cell clamp technique. PV cardiomyocytes had different beating rates at low (22-25 degrees C), normal (38-39 degrees C) and high (40-41 degrees C) temperatures (0.9 +/- 0.1, 3.2 +/- 0.4, 6.4 +/- 0.6 Hz, respectively; p < 0.001). There were different action potential durations and incidences of delayed afterdepolarization in PV cardiomyocytes with pacemaker activity (31, 59, 63%; p < 0.05), PV cardiomyocytes without pacemaker activity (16, 47, 60%; p < 0.001), and atrial myocytes (0, 0, 21%; p < 0.05). However, oscillatory afterpotentials were only found in PV cardiomyocytes with pacemaker activity at normal (50%) or high (68%) temperatures, but not at low temperatures (p < 0.001). Both PV and atrial cardiomyocytes had larger transient inward currents and inward rectified currents at high temperatures. Additionally, PV cardiomyocytes with and without pacemaker activity had larger pacemaker currents at higher temperatures. This study demonstrated that PV cardiomyocytes have an increase in arrhythmogenic activity at high temperatures because of enhanced automaticity, induced triggered activity, or shortening of action potential duration.

Для цитирования: Chen Yi-Jen, Chen Yao-Chang, Chan Paul, Lin Cheng-I, Chen Shih-Ann. Temperature regulates the arrhythmogenic activity of pulmonary vein cardiomyocytes.. Journal of biomedical science. 2003. DOI: 10.1007/bf02256115.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.