MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0735-1097(02)02530-5

Медицинская библиотека · Journal of the American College of Cardiology · 2002

QRST subtraction combined with a pacemap catalogue for the prediction of ectopy source by surface electrocardiogram in patients with paroxysmal atrial fibrillation.

Choi Kee-Joon, Shah Dipen C, Jais Pierre, Hocini Meleze, Macle Laurent, Scavee Christophe, Weerasooriya Rukshen, Raybaud Florence, Clementy Jacques, Haissaguerre Michel

Сравнительное исследованиеОценочное исследованиеСтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study evaluated the use of ectopic P-wave morphology to localize pulmonary vein (PV) and non-PV sources of atrial ectopics in patients with paroxysmal atrial fibrillation (PAF).

BACKGROUND

The vectorial information embodied in the morphology of ectopic P waves is concealed by overlying T waves.

METHODS

The P-wave morphology of 56 ectopics was prospectively analyzed in 44 patients with PAF (age, 52 +/- 12 years; 36 male) by subtracting the adjacent QRST from the QRST-ectopic P-wave complex using custom-designed software. Subtraction fidelity was validated in 15 other patients (55 +/- 19 years, 11 male) by comparing drive beats with simulated ectopics (S2 from the same site) unmasked by subtracting overlying QRST. An algorithm combined with PV pacemaps was used to predict PV sources. Subtracted ectopic P-wave morphologies after PV disconnection were compared with PV and non-PV site pacemaps. Localization was confirmed by mapping and successful ablation.

RESULTS

A > or =10-lead electrocardiogram (ECG) match was observed in 92% of 644 simulated ectopics (coupling intervals: 190 to 520 ms). In PAF patients, 37 spontaneous ectopics originated from the PV, while 19 were noted after PV disconnection. Using the P-wave algorithm alone, correct prediction of PV origin was achieved in 30/37 ectopics (81%). Combination with PV pacemaps allowed correct prediction in 34/37 (92%). After PV disconnection, ECG localization predicted successful ablation sites in 16/19 (84%).

CONCLUSIONS

Comparison of subtracted ectopic P waves with a pacemap catalogue provides a simple and accurate 12-lead ECG-based method for localization, which can facilitate ablation of arrhythmia triggers irrespective of origin from the PV or elsewhere.

Для цитирования: Choi Kee-Joon, Shah Dipen C, Jais Pierre, Hocini Meleze, Macle Laurent, Scavee Christophe, Weerasooriya Rukshen, Raybaud Florence, Clementy Jacques, Haissaguerre Michel. QRST subtraction combined with a pacemap catalogue for the prediction of ectopy source by surface electrocardiogram in patients with paroxysmal atrial fibrillation.. Journal of the American College of Cardiology. 2002. DOI: 10.1016/s0735-1097(02)02530-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.