MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjopen-2023-073843

Медицинская библиотека · BMJ open · 2023

Determining efficacy of dynamic multimedia bowel preparation instructions versus standard instructions on adenoma detection and patient reported measures (DIGICLEAN trial): a study protocol for a multicentre, colonoscopist-blinded, randomised controlled trial.

Au Michael, Low Patrick, Rennie Michael, Mohseni Marriam, Song Yang, Kim Narae, Baraty Brandon, Mitrev Nikola, He Emily, Ho Vincent, Leong Rupert, Kariyawasam Viraj

Протокол клинического исследованияСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

Colonoscopy plays important roles in bowel cancer screening and treatment. Poor bowel preparation occurs in 20-25% of colonoscopies. This negatively impacts adenoma and sessile serrated lesion detection rates, procedural time, requirement for repeat colonoscopies, healthcare costs and likelihood of patient withdrawal from screening programmes. It is unclear whether a combination of multimedia modalities can improve bowel preparation quality, adenoma detection rates and patient-reported measures in those undergoing colonoscopy assessment.

METHODS

The DIGICLEAN trial is a prospective, parallel, multicentre, colonoscopist-blinded, randomised controlled trial. The trial will enrol 1294 participants aged 45 years and older who are indicated for a colonoscopy as an outpatient with a positive faecal occult blood test, iron deficiency anaemia or rectal bleeding. Participants will be randomised into the interventional arm, where bowel preparation instructions are delivered via a web-based application which uses scheduled short messaging service, regular patient survey assessment, email and videos; or the control arm, where routine standard written, verbal or emailed instructions are administered. The web-based application will assess patient-reported bloating, constipation and dietary adherence leading up to the colonoscopy. Depending on patient responses, additional aperients may be encouraged digitally in the interventional arm with same instructions made available in written format for the control arm. Patient-reported measures will be collected in both arms the day after the procedure using the validated Newcastle ENDOPREM questionnaire. In some sites, participants will undergo digital pre-anaesthetic screening as well. The co-primary endpoints are the adenoma detection rates and patient-reported measures taken after the colonoscopy.

ETHICS AND DISSEMINATION: Ethics approval for this study was obtained from the Western Sydney Local Health District Human Research Ethics Committee (2022/ETH00059). Findings will be reported at national and international gastroenterology meetings and published in peer-reviewed journals.

TRIAL REGISTRATION NUMBER: ACTRN12622000747729.

Для цитирования: Au Michael, Low Patrick, Rennie Michael, Mohseni Marriam, Song Yang, Kim Narae, Baraty Brandon, Mitrev Nikola, He Emily, Ho Vincent, Leong Rupert, Kariyawasam Viraj. Determining efficacy of dynamic multimedia bowel preparation instructions versus standard instructions on adenoma detection and patient reported measures (DIGICLEAN trial): a study protocol for a multicentre, colonoscopist-blinded, randomised controlled trial.. BMJ open. 2023. DOI: 10.1136/bmjopen-2023-073843.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.