m+Medelevator.RU
← Поиск публикаций
Stroke · 1997

Transcranial Doppler ultrasound criteria for hemodynamically significant internal carotid artery stenosis based on residual lumen diameter calculated from en bloc endarterectomy specimens.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Can U, Furie K L, Suwanwela N, Southern J F, Macdonald N R, Ogilvy C S, Buonanno F S, Koroshetz W J, Kistler J P

Аннотация

BACKGROUND AND PURPOSE: Transcranial Doppler (TCD) is often used in conjunction with carotid duplex ultrasonography (CDUS) to evaluate the hemodynamic significance of internal carotid artery (ICA) stenosis. We examined the sensitivity and specificity of TCD criteria for detection of a hemodynamically significant stenosis (residual lumen diameter < 1.5 mm) at the origin of the ICA.

METHODS: We selected patients who underwent carotid end-arterectomy (CEA) and had preoperative TCD data available. Eighty-one patients underwent transorbital evaluation, 49 of whom also had transtemporal TCD performed. The endarterectomy specimens were removed en bloc and sectioned, and the minimal residual lumen diameter calculated by computer analysis.

RESULTS: For the transorbital approach, the strongest indicators of a residual lumen diameter < 1.5 mm were reversed flow in the ipsilateral ophthalmic artery and a > 50% peak systolic velocity difference between the carotid siphons (distal ICAs) in patients with unilateral ICA origin stenosis. They were 100% specific and 31% and 26% sensitive, respectively. For the transtemporal approach in patients with a unilateral stenosis, a > 35% difference in ipsilateral middle cerebral artery (MCA) peak systolic velocity relative to the contralateral MCA or a > 50% difference in contralateral anterior cerebral artery (ACA) peak systolic velocity relative to the ipsilateral ACA were 100% specific for identifying a residual lumen diameter of < 1.5 mm. Sensitivities were 32% and 43%, respectively. Irrespective of contralateral stenosis, a > 35% difference in ipsilateral MCA peak systolic velocity relative to the ipsilateral posterior cerebral artery had a 100% specificity and a 23% sensitivity for detecting a < 1.5 mm minimal residual lumen diameter.

CONCLUSIONS: Although the TCD sensitivity for detecting a hemodynamically significant stenosis is relatively low, it can be highly specific (up to 100%). We conclude that TCD enhances the specificity of highly sensitive CDUS criteria for detecting a hemodynamically significant ICA stenosis.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты